Research on Application Status of Water-cooled Radiator of Rail Transit
A variety of different structures of water-cooled radiators used in rail transportation were tested and compared. The effects of different types of flow channels on the flow resistance and heat dissipation performance of radiators were compared, and the ...
Xiong WANG +4 more
doaj +1 more source
Fault Analysis and Preventive Measures for Bulging of Water-cooled Radiator
Aiming to the problem of bulging of water-cooled radiator for power module, it conducted a series of experiments based on three probable reasons and did some theory calculation.
WANG Xingzhi +3 more
doaj +2 more sources
Design and Optimization of Water-cooled Radiator for 6-inch Thyristor Based on Fluent
It presents a water-cooled radiation system for 6-inch thyristor and its model. With Fluent software, radiation process is simulated through finite element analysis as well as standard k- ε turbulence model, which follows computations on both N-S ...
XIONG Hui +4 more
doaj +2 more sources
Effects of Mesh Size on Simulation Results of Water-Cooling Radiator for IGBT Module
It comparatively analyzed CFD simulation results of IGBT water-cooled radiator with 0.5mm, 1mm and 2mm mesh size. Research results showed that the scheme of mesh size 0.5mm tended to be more accurate than the others on capturing the flow information and ...
丁杰, 唐玉兔, 忻力, 胡昌发
doaj +2 more sources
Water-cooled radiator design and optimization research for high power 3D-Sip system encapsulate [PDF]
For high power package water-cooled radiator of 3D-Sip system and by using the finite element software ANSYS numerical simulation analysis of the geometrical parameters and fluid velocity affecting the performance of radiator cooling, the condition of air cooling water-cooled radiator fin thickness, spacing, and affect the performance of water cooled ...
Tianshou Liang, Dejian Zhou, Jijun Zhang
exaly +2 more sources
Design of High Voltage IGBT Converter Module for High Power Test Bed
High-voltage IGBT converter module applies the integration design including the circuits and components, in which the design of laminated bus-bar and radiator is a challenge.
LIU Feng +4 more
doaj +2 more sources
Evaluation of Loss Coefficient For Stand Alone Radiator [PDF]
In the UK, domestic heating contributes to about 40% of annual energy consumption. Effective and efficient heating systems are essential to drive the cost of heating down.
Barrans, Simon +3 more
core +6 more sources
Enhancing radiator cooling capacity: A comparative study of nanofluids and water/EG mixtures. [PDF]
Tetik T, Karagoz Y.
europepmc +2 more sources
A water-cooled mirror system for synchrotron radiation [PDF]
Abstract This paper describes the design and performance of a directly-cooled soft X-ray mirror system which has been developed at Lawrence Berkeley Laboratory for synchrotron radiation beam lines in which mirror thermal distortion must be minimized for acceptable optical performance ∗ .
DiGennaro, R. +5 more
openaire +1 more source
Water-cooled ion-milled diffraction gratings for the synchrotron radiation community [PDF]
Abstract Key technical and strategic choices are reviewed, leading to the fabrication method of ion-milled grating grooves for the monochromators at the Advanced Light Source (ALS) at Lawrence Berkeley Laboratory (LBL), and for other synchrotrons. Several laboratories and their industrial partners have joined to manufacture gratings with close to ...
McKinney, W. R. +2 more
openaire +2 more sources