Ineffectiveness of Water Mist Spray to the Upper Body of Healthy Adults in Suppressing Core Temperature Under Windless Environment [PDF]
Background: Global warming has increased heat-related illness concerns. Water misting is used for workplace cooling, but its effect on core body temperature is unclear.
Kimie Fukuzawa +5 more
doaj +2 more sources
Research on N2-inhibitor-water mist fire prevention and extinguishing technology and equipment in coal mine goaf. [PDF]
In this study, a new type of N2-inhibitor-water mist (NIWM) technology was proposed to resolve the problem of fire prevention and extinguishing in the goaf of coal mine. The corresponding equipment was designed and manufactured.
Hongwei Liu, Fei Wang
doaj +2 more sources
Full-Scale Experimental Investigation of Temperature Distribution and Smoke Flow in a Road Tunnel with a Novel Water Mist Fire Fighting System [PDF]
This study presents a novel water mist fire fighting system that integrates water mist sprays and water mist curtains, designed to achieve simultaneous fire suppression, thermal insulation, and smoke control.
Shouzhong Feng, Deyuan Kan, Chao Guo
doaj +2 more sources
Effect of Water Mist Cooling on Microstructure of Hypereutectic Al-Si Alloy [PDF]
The work is a continuation of research on the use water mist cooling in order to increase efficiency of die-casting aluminum alloys using multipoint water mist cooling system.
Władysiak R., Kozuń A.
doaj +3 more sources
Fire Extinction Analysis and OH-PLIF Visualization of the Methane–Air Premixed Laminar Flame Interacting with the Downward Water Mist [PDF]
In this study, a McKenna burner made for calibration is used to generate the laminar flame with the equivalence ratio of 0.78~2.0. The effect of the downward water mist spray on the extinction of the methane–air premixed laminar flame is investigated ...
Yangpeng Liu +5 more
doaj +2 more sources
Study of the effectiveness of water mist curtain in blocking fire-induced smoke in tunnel by means of CFD simulations [PDF]
Tunnel fire smoke control is an important issue in the area of tunnel fire safety. Inspired by fire compartmentation in buildings, it is worth investigating whether a tunnel can be partitioned by a water mist system into a fire zone and safety zones.
Sun Jiayun +4 more
doaj +1 more source
A variety of experimental configurations including different water mist obstacles, are used to investigate the combined effects of obstacles and water mist upon the gas explosion.
Bin Zhang +10 more
doaj +1 more source
Research on an ultrafine water mist partition multistage dust suppression system in underground excavation tunnel. [PDF]
Jing D +6 more
europepmc +3 more sources
Water-air aerosol cooling of rows of cylindrical elements under conditions of natural convection [PDF]
The article notes the disadvantages of application of dry cooling towers and air-cooled condensers for heat elimination. The cooling air humidifying is considered as a prevalent method of these heat removers efficiency increasing.
Abed Akram +2 more
doaj +1 more source
Study on the suppression of pyrolytic gas flames in red pine wood by water mist
The suppression of forest fires has been one of the important research directions in the field of fire safety, fine water mist because of the advantages of easy access to materials, low price and no pollution to become one of the commonly used inhibitors
Li Haoyang +3 more
doaj +1 more source