Results 201 to 210 of about 9,355,325 (300)
Focusing scattered light through live tissue with channel-selected wavefront shaping. [PDF]
Jia C +8 more
europepmc +1 more source
ABSTRACT Background Electrographic flow (EGF) mapping is an FDA 510(k)‐cleared method for visualizing atrial activation wavefronts in atrial fibrillation (AF). Its clinical efficacy in detecting AF sources was demonstrated in the FLOW‐AF randomized controlled trial, and the underlying machine learning strategy used to develop and refine EGF source ...
Steven Castellano +9 more
wiley +1 more source
Wavefront sensing at a high-repetition-rate X-ray free-electron laser. [PDF]
Guest T +18 more
europepmc +1 more source
ABSTRACT Introduction Electrogram peak‐to‐peak voltage depends on atrial wall structure and mapping configuration. We evaluated the relationship between computed tomography–derived atrial wall thickness, intramyocardial fat, myocardial muscle thickness, and electrogram voltage obtained with omnipolar, bipolar, and unipolar mapping.
Cecilia Granata +21 more
wiley +1 more source
SWIFT-Mamba: A Lightweight State Space Model Toward In Situ Verification of Airborne Wavefront Sensing Signals. [PDF]
Ma J, Wang H, Fan Y, Jiang W, Su J.
europepmc +1 more source
Hyperspectral tomographic diffractive microscopy: Development and applications
Abstract Tomographic Diffractive Microscopy (TDM) provides label‐free three‐dimensional imaging of transparent samples with resolution surpassing confocal limits. At IRIMAS, successive instrumental developments since 2009 have enhanced TDM capabilities through transmission, reflection, isotropic, polarisation‐sensitive, and dual‐view configurations ...
Leonardo Pestana Legori +4 more
wiley +1 more source
Changes in Corneal Biomechanics and Wavefront Following Eyelid Surgery. [PDF]
Abhaypal K +5 more
europepmc +1 more source
Beyond single cells: Ten years of commercial lattice light‐sheet microscopy
Abstract Lattice light‐sheet microscopy (LLSM) enables gentle, rapid, volumetric fluorescence imaging of living biological systems. The technique employs Bessel beam interference to produce a light‐sheet which retains its thickness over a relatively large field‐of‐view compared to other light‐sheets.
Helena L. E. Coker, David S. Corcoran
wiley +1 more source
On-Chip Mid-Infrared Wavefront Sensing Based on Vectorial Photocurrent Manipulation. [PDF]
Ye T +8 more
europepmc +1 more source
Abstract Virtual articulators require accurate spatial orientation of digital casts for meaningful occlusal analysis during prosthesis design. Current methods for establishing this orientation rely on facial scanning, cone‐beam computed tomography, electronic jaw tracking, or arbitrary population–based values. This proof‐of‐concept technique presents a
Mohamed Sherif Omar +3 more
wiley +1 more source

