Results 41 to 50 of about 3,167,411 (345)
The stability of grid-connected wind power system (GCWPS) is prone to deteriorate due to the impedance interaction between wind turbines and the weak grid.
Haining Wang +5 more
doaj +1 more source
New power decoupling strategy for grid-connected inverter under weak power grid
This study analyzes the power coupling in a weak power grid, and designs a novel decoupling method for the coupling power with multi harmonic frequency on the dc bus.
Wai Rong-Jong, Wang Yu
doaj +1 more source
An assessment of the stability and performance of current controllers with harmonic compensators is presented for an inductive-capacitive-inductive (LCL)-filtered grid-connected inverter under distorted weak grid conditions.
Seung-Jin Yoon +2 more
doaj +1 more source
Estimates of Stellar Weak Interaction Rates for Nuclei in the Mass Range A=65-80 [PDF]
We estimate lepton capture and emission rates, as well as neutrino energy loss rates, for nuclei in the mass range A=65-80. These rates are calculated on a temperature/density grid appropriate for a wide range of astrophysical applications including ...
Fuller, George M., Pruet, Jason
core +3 more sources
Voltage source inverters (VSIs) with vector control based on phase-locked loop (PLL) suffer instability when connecting to a very weak AC grid (short circuit ratio (SCR)$ < $1.3).
Chuanyue Li +4 more
semanticscholar +1 more source
Control Strategy of Vienna Rectifier With LCL Filter Under Weak Grid Conditions
For the LCL type filter, there is a natural resonance peak, and the change of the grid impedance in the actual power grid will further affect the stability of the rectifier.
Yuanpeng FENG +3 more
doaj +1 more source
An intelligent control method using recurrent wavelet fuzzy neural network (RWFNN) is proposed to improve the low-voltage ride through (LVRT) performance of a two-stage photovoltaic (PV) power plant under grid faults for the weak grid conditions.
Faa-Jeng Lin +3 more
doaj +1 more source
Power-Synchronized Grid-Following Inverter Without a Phase-Locked Loop
This paper proposes a power-synchronized control strategy for grid-following inverters (GFLIs) to regulate their power exchange with the grid without any need for sensing/regulating the point of connection voltage.
Behrooz Bahrani
doaj +1 more source
Velocity-gauge real-time TDDFT within a numerical atomic orbital basis set [PDF]
The interaction of laser fields with solid-state systems can be modeled efficiently within the velocity-gauge formalism of real-time time dependent density functional theory (RT-TDDFT). In this article, we discuss the implementation of the velocity-gauge
Kas, J. J. +6 more
core +3 more sources
The voltage control loop of a virtual synchronous generator (VSG) is typically governed by a conventional reactive power-voltage droop control, which may exhibit instability when encountering disturbances or operating under weak grid conditions.
Hayder Hassan Abbas +2 more
doaj +1 more source

