Results 41 to 50 of about 528,108 (265)
ABSTRACT Purpose Pediatric central nervous system (CNS) tumors often recur despite multimodality therapy. Although re‐irradiation (re‐RT) has historically been limited by concerns for severe late toxicities, modern techniques have renewed interest in this approach. Proton therapy provides dosimetric advantages that may enable curative re‐treatment with
Jin‐Ho Song +15 more
wiley +1 more source
The spin-exchange relaxation-free comagnetometer (SERFC) is of important research value compared to existing high-precision gyroscopes because of its extremely high theoretical limit sensitivity and long-term stability, in which one significant limiting ...
Zhihong Wu +11 more
doaj +1 more source
Measuring measurement–disturbance relationships with weak values
Using formal definitions for measurement precision ε and disturbance (measurement backaction) η, Ozawa [Phys. Rev. A 67, 042105 (2003)] has shown that Heisenberg's claimed relation between these quantities is false in general. Here we show that the quantities introduced by Ozawa can be determined experimentally, using no prior knowledge of the ...
Lund, AP, Wiseman, HM
openaire +6 more sources
Weak measurements with entangled probes [PDF]
Encoding the imaginary part of a weak value onto an initially entangled probe can modify its entanglement content - provided the probe observable can distinguish between states of different entropies. Apart from fundamental interest, this result illustrates the utility of the imaginary weak value as a calculational tool in certain entanglement ...
Menzies, David, Korolkova, Natalia
openaire +2 more sources
ABSTRACT Background Survivors of childhood acute lymphoblastic leukemia (ALL) often exhibit early deficits in muscle and movement competence, which can compromise long‐term health. Integrative neuromuscular training (INT), a multifaceted approach combining fundamental movement activities with strength exercises, may help address these deficits during ...
Anna Maria Markarian +7 more
wiley +1 more source
Background: Myocardial ischemia (MI) is a major cause of morbidity and mortality worldwide and requires timely and reliable detection. Although Spin-Exchange Relaxation-Free (SERF) magnetocardiography (MCG) provides femtotesla-level sensitivity for ...
Keyi Li +10 more
doaj +1 more source
Improving the Precision of Weak Measurements by Postselection Measurement
12 pages, 1 figure. V3: close to the published version. V2: analysis of squeezed coherent state and comparison between SNR and Fisher information added, supplemental material ...
Pang, Shengshi, Brun, Todd A.
openaire +4 more sources
ABSTRACT Background 131I‐metaiodobenzylguanidine (131I‐MIBG) radiotherapy is a key treatment for relapsed and refractory (R/R) neuroblastoma (NB). Patients with R/R disease treated in the modern era are increasingly exposed to anti‐GD2 immunotherapy, which exerts selective pressure and may modify both tumor cell state and microenvironment.
Benjamin J. Lerman +7 more
wiley +1 more source
Atomic magnetometers (AMs) that use alkali vapors, such as rubidium, are among the most sensitive sensors for magnetic field measurement. They commonly use polarization differential detection to mitigate common-mode noise.
Cui Zhibo +7 more
doaj +1 more source
Bio-electric fields—manifested as Electroencephalogram (EEG), Electrocardiogram (ECG), Electromyogram (EMG), and Electrooculogram (EOG)—are fundamental to modern medical diagnostics but often suffer from severe data imbalance, scarcity, and environmental
Jiaqi Liang +6 more
doaj +1 more source

