The Effects of Biomaterial Implant Wear Debris on Osteoblasts [PDF]
Aseptic loosening subsequent to periprosthetic osteolysis is the leading cause for the revision of arthroplasty failure. The biological response of macrophages to wear debris has been well established, however, the equilibrium of bone remodeling is not ...
Li Zhang +6 more
doaj +5 more sources
A Permanent Magnet Ferromagnetic Wear Debris Sensor Based on Axisymmetric High-Gradient Magnetic Field [PDF]
The detection of wear debris in lubricating oil is effective for determining current equipment operating conditions for fault diagnosis. In this paper, a permanent magnet ferromagnetic wear debris sensor is proposed that is composed of a compact ...
Bin Fan +5 more
doaj +2 more sources
An automated system for polymer wear debris analysis in total disc arthroplasty using convolution neural network [PDF]
Introduction: Polymer wear debris is one of the major concerns in total joint replacements due to wear-induced biological reactions which can lead to osteolysis and joint failure. The wear-induced biological reactions depend on the wear volume, shape and
Sushil Kandel +5 more
doaj +2 more sources
A Wear Debris Segmentation Method for Direct Reflection Online Visual Ferrography [PDF]
Wear debris in lube oil was observed using a direct reflection online visual ferrograph (OLVF) to monitor the machine running condition and judge wear failure online.
Song Feng +5 more
doaj +2 more sources
A Novel Method for Detecting Ferromagnetic Wear Debris with High Flow Velocity [PDF]
Inductance detection is an important method for detecting wear debris in ship lubricating oil. Presently, an LCR (inductance, resistance, capacitance) meter is generally used to detect wear debris by measuring the inductance change of the sensing coil ...
Feng Wang +6 more
doaj +2 more sources
Improving Sensitivity of a Micro Inductive Sensor for Wear Debris Detection with Magnetic Powder Surrounded [PDF]
The inductive detection of wear debris in lubrication oil is an effective method to monitor the machine status. As the wear debris is usually micro scale, a micro inductive sensor is always used to detect them in research papers or high-tech products ...
Liankun Liu +7 more
doaj +2 more sources
Therapeutic Potential of Targeting Ferroptosis in Periprosthetic Osteolysis Induced by Ultra-High-Molecular-Weight Polyethylene Wear Debris [PDF]
Background/Objectives: Periprosthetic osteolysis is the primary cause of arthroplasty failure in the majority of patients. Mechanistically, wear debris released from the articulating surfaces of a prosthesis initiates local inflammation and several modes
Takuya Ogawa +14 more
doaj +2 more sources
Multichannel Inductive Sensor Based on Phase Division Multiplexing for Wear Debris Detection [PDF]
Inductive wear debris sensor has been widely used in real time machine lubricant oil condition monitoring and fault forecasting. However, the small sensing zone, which is designed for high sensitivity, of the existing sensors leads to low throughput.
Sen Wu +6 more
doaj +2 more sources
Real-Time Ferrogram Segmentation of Wear Debris Using Multi-Level Feature Reused Unet [PDF]
The real-time monitoring and fault diagnosis of modern machinery and equipment impose higher demands on equipment maintenance, with the extraction of morphological characteristics of wear debris in lubricating oil emerging as a critical approach for real-
Jie You +5 more
doaj +2 more sources
Hyper-Heuristic Capacitance Array Method for Multi-Metal Wear Debris Detection [PDF]
Online detection of fatigued wear debris in the lubricants of aero-engines can provide warning of engine failure during flight, thus having great economic and social benefits.
Yanshan Sun, Lecheng Jia, Zhoumo Zeng