Results 131 to 140 of about 452,681 (253)

Erratum: Confirmation of the topology of the Wendelstein 7-X magnetic field to better than 1:100,000. [PDF]

open access: yesNat Commun, 2017
Pedersen TS   +9 more
europepmc   +1 more source

Design and experimental verification of a multi-pass ECRH plasma start-up scenario at a reduced magnetic field of 1.8 T at W7-X

open access: yesNuclear Fusion
Wendelstein 7-X (W7-X) nominally operates at a magnetic field of 2.5 T, but operation at a lower magnetic field strength is desired. The electron cyclotron resonance heating (ECRH) system of W7-X operates at 140 GHz, corresponding to second harmonic (X2)
Niklas Simon Polei   +14 more
doaj   +1 more source

Microwave diagnostic at Wendelstein 7-X

open access: yesJournal of Instrumentation
Abstract At Wendelstein 7-X (W7-X), the world's largest superconducting stellarator with a five-fold symmetry and reduced neoclassical transport, a broad suite of microwave diagnostics is installed and operated. Due to the robustness of in-vessel components and transmission lines against the harsh environment in ...
Krämer-Flecken, A.   +15 more
openaire   +2 more sources

Key results from the first plasma operation phase and outlook for future performance in Wendelstein 7-X. [PDF]

open access: yesPhys Plasmas, 2017
Sunn Pedersen T   +18 more
europepmc   +1 more source

Bootstrapping of Corneal Optical Coherence Tomography Data to Investigate Conic Fit Robustness. [PDF]

open access: yesJ Clin Med, 2023
Langenbucher A   +6 more
europepmc   +1 more source

Characterizing core and edge turbulence regimes with fluctuation imaging diagnostics in Wendelstein 7-X

open access: yesNuclear Fusion
Two density fluctuation imaging systems, phase contrast imaging (PCI) and gas puff imaging (GPI) measure spatially resolved density fluctuations with high time resolution throughout the core plasma (PCI) and in the scrape-off layer (GPI) of the ...
A. von Stechow   +21 more
doaj   +1 more source

Prediction of corneal power vectors after cataract surgery with toric lens implantation-A vector analysis. [PDF]

open access: yesPLoS One, 2023
Langenbucher A   +4 more
europepmc   +1 more source

Impact of drift flows and turbulence on island divertor operation in Wendelstein 7-X

open access: yesNuclear Fusion
The island divertor in Wendelstein 7-X employs a chain of stationary magnetic islands to separate the confined plasma from the divertor targets. In this configuration, the scrape-off layer (SOL) exhibits complex patterns of counter-propagating bi-normal ...
Carsten Killer   +10 more
doaj   +1 more source

Meridional ocular magnification after cataract surgery with toric and non-toric intraocular lenses. [PDF]

open access: yesGraefes Arch Clin Exp Ophthalmol, 2022
Langenbucher A   +5 more
europepmc   +1 more source

Home - About - Disclaimer - Privacy