Results 11 to 20 of about 122,201 (309)
Study of 20 Hz high spatial-temporal resolution monochromatic X-ray dynamic micro-CT
BackgroundDynamic micro-computed tomography (micro-CT) using monochromatic X-ray offers higher density resolution and lower radiation damage compared to that using white X-ray, however balancing its imaging spatial and temporal resolution is challenging.
QIU Zhengjie +5 more
doaj +1 more source
Study of the Microfocus X-Ray Tube Based on a Point-Like Target Used for Micro-Computed Tomography. [PDF]
For a micro-Computed Tomography (Micro-CT) system, the microfocus X-ray tube is an essential component because the spatial resolution of CT images, in theory, is mainly determined by the size and stability of the X-ray focal spot of the microfocus X-ray ...
Rifeng Zhou +4 more
doaj +1 more source
The Mt. Rudnaya MSS-ISS (monosulfide and intermediate solid solution) fine-grained ores from a NE termination of Norilsk 1 deposit were analyzed using a combination of X-ray computed micro tomography, spectral X-ray computed micro tomography and scanning
J. Sittner +10 more
doaj +1 more source
Estimating the 3D Printing Defects by Micro-Computed Tomography
Micro-computed tomography (µ-CT) is an X-ray technique with (sub)micron resolution, [...]
Doina Dimonie +6 more
doaj +1 more source
Fast reconstruction of X-ray dynamic micro-CT based on GPU parallel computing
BackgroundMassive projection data are produced by user experiments with the X-ray dynamic micro-computed tomography (CT) method on the X-ray imaging beamline at Shanghai synchrotron radiation facility (SSRF).
ZHANG Yuan +5 more
doaj +1 more source
X-ray computed micro-tomography of reticulated vitreous carbon [PDF]
Abstract The 3D structure of various grades of reticulated vitreous carbon (RVC) is studied by X-ray computed micro-tomography (μCT). The settings required to estimate the bulk volumetric surface area, Ae, accurately are investigated and the results are compared to those obtained from scanning electron microscopy and from pressure drop measurements ...
Arenas, Luis F. +3 more
openaire +3 more sources
The physico-elemental profiles of commercially attained and roasted organic coffee beans from Ethiopia, Colombia, Honduras, and Mexico were compared using light microscopy, X-ray micro-computed tomography, and external beam particle induced X-ray ...
Karen J. Cloete +6 more
doaj +1 more source
Effectiveness of endodontic retreatment using WaveOne Primary files in reciprocating and rotary motions [PDF]
ObjectivesThis study evaluated the efficiency of WaveOne Primary files (Dentsply Sirona) for removing root canal fillings with 2 types of movement: reciprocating (RCP) and continuous counterclockwise rotation (CCR).Materials and MethodsTwenty mandibular ...
Patricia Marton Costa +4 more
doaj +1 more source
The Activation of Mg Powder Promoted by Chloride and Activation Mechanism
Magnesium has bright market prospects such as generating thrust for under water engines and hydrogen production. However, the passive oxide film on the surface of magnesium powder prevents the further reaction of magnesium with water at room temperature.
Xiaoxuan Wang +7 more
doaj +1 more source
In-situ Analysis of Laminated Composite Materials by X-ray Micro-Computed Tomography and Digital Volume Correlation [PDF]
The complex mechanical behaviour of composite materials, due to internal heterogeneity and multi-layered composition impose deeper studies. This paper presents an experimental investigation technique to perform volume kinematic measurements in composite ...
A Germaneau +32 more
core +3 more sources

