Results 91 to 100 of about 127,048 (210)
The effects of crosslinking byproducts on the electrical properties of low density polyethylene
Crosslinked polyethylene (XLPE) is widely used for high voltage insulation in power transmission systems. However, it has been found that, after crosslinking with Dicumyl Peroxide (DCP), the crosslinking byproducts such as acetophenone, ?-methylstyrene ...
Hussin, Nuriziani
core +1 more source
The space charge accumulation in the heterogeneous insulation composed of cross‐linked polyethylene (XLPE) cable and silicone rubber (SiR) accessory poses a serious threat to the safe operation of the high voltage direct current (HVDC) cable.
Yani Wang +6 more
doaj +1 more source
Environmentally friendly Crosslinked Polyethylene (XLPE) cables represent a new development trend. XLPE exhibits good electrical properties and recyclability.
Yujia Cheng +3 more
doaj +1 more source
Al2O3 and SiO2 nanofillers have been widely used to improve the insulation performance of cross-linked polyethylene (XLPE) for high-voltage power cables.
Shihu Yu +6 more
doaj +1 more source
This study presents a detailed numerical analysis of the electric field distribution in cross-linked polyethylene (XLPE) dielectric insulators used in photovoltaic (PV) power transmission systems.
M.P. Buryk +5 more
doaj +1 more source
The paper presents space charge distributions under opposite voltage polarities in full size cross-linked polyethylene power cables using the pulsed electro-acoustic technique.
Fothergill, J C, Fu, M, Chen, G
core +1 more source
Cross-linked polyethylene (XLPE) is commonly used within high voltage cable insulation. It has improved thermal and mechanical resistance compared to normal low density polyethylene (LDPE).
Dao, N L, Swingler, S G, Lewin, P L
core +1 more source
Although XLPE cables are widely used in power transmission and distribution systems, their insulating properties are susceptible to degradation due to thermal aging. In order to clarify the influence law of the thermal aging process on the structural and
Yamei Li +5 more
doaj +1 more source
Space Charge in Polyethylene under AC Electric Stress using the Pulsed Electroacoustic Method
This paper reports on space charge in XLPE planar samples of approximately 220 ?m thick subjected to dc 30 kV/mm and 1 Hz, 10 Hz and 50 Hz ac 30 kVpk/mm conditions for 24 hours. Measurement of space charge was carried out using the pulsed electroacoustic
Tanaka, Y +5 more
core +1 more source
This paper reports on the result of space charge evolution in cross-linked polyethylene (XLPE) planar samples of approximately 220 ?m thick. The space charge measurement technique used in this study is the PEA method.
Tanaka, Y +5 more
core +1 more source