Results 81 to 90 of about 127,048 (210)

Treeing phenomenon of thermoplastic polyethylene blends for recyclable cable insulation materials

open access: yesAIP Advances, 2017
Owing to its good recyclability and low processing energy consumption, non-crosslinked polyethylene blends (e.g. LLDPE-HDPE blends) are considered as one of potential environmental-friendly substitutions for crosslinked polyethylene (XLPE) as cable ...
Lunzhi Li   +6 more
doaj   +1 more source

The Extra‐Low Frequency Dielectric Analysis Method for Evaluating Byproducts of Cross‐Linked Polyethylene Cable Insulation Materials

open access: yesHigh Voltage
Cross‐linking byproducts in the cross‐linked polyethylene (XLPE) cable insulation material significantly affect the insulation properties of XLPE, and the non‐destructive detection method for cross‐linking byproducts during cable degassing process still ...
Wenpeng Li   +8 more
doaj   +1 more source

DC electric field distribution in planar dielectric in the presence of space charge [PDF]

open access: yes, 2007
Electric field in a dielectric material under dc conditions is determined by conductivity of the material. It is well known that the dc conductivity is a function of both temperature and electric field.
Z. Xu   +5 more
core   +1 more source

The Influence of Material Modification and Residues on Space Charge Accumulation in XLPE for DC Power Cable Application

open access: yes, 2007
The effects of material modification and cross-linking by-products (residues) quantity on space charge accumulation and decay in XLPE have been investigated using the pulsed electro-acoustic technique.
Fothergill, J C   +3 more
core   +1 more source

Correlation of Macroscopic Interface Breakdown Characteristics and Microscopic Particle Motions at the XLPE-SiR Insulation Interface of Cable Joints

open access: yesEnergies
This paper explores the correlation between the macroscopic breakdown behavior and microscopic particle motion of cable joint cross-linked polyethylene–silicone rubber (XLPE-SiR) insulation interface breakdown. Firstly, based on the characteristics of Pd
Kai Wang   +8 more
doaj   +1 more source

The effect of degassing on morphology and space charge

open access: yes, 2004
It is believed that space charge buildup in cross-linked polyethylene (XLPE) insulation is the main cause for premature failure of underground power cables. The space charge activities in XLPE depend on many factors such as additives, material treatment,
Chong, Y L, Chen, G, Ho, Y F F
core   +2 more sources

Performance Evolution and Ageing Characteristics of Crosslinked Polyethylene Insulation for HVDC Cables After Field Operation

open access: yesHigh Voltage
The ± 200 kV direct current (DC) cables of the Zhoushan Transmission Project were targeted, and crosslinked polyethylene (XLPE) insulation samples were prepared from faulty and spare cables.
Ying Liu, Jiazhu Yu, Meng Ma
doaj   +1 more source

Effect of applied DC voltages and temperatures on space charge behaviour of multi-layer oil-paper insulation

open access: yes, 2009
In this paper, space charge in a multi-layer oil-paper insulation system was investigated using the pulsed electroacoustic (PEA) technique. A series of measurements had been carried following subjection of the insulation system to different applied ...
Liao, R, Fu, M, Tang, Chao, Chen, George
core   +1 more source

Space charge accumulation under the effects of temperature gradient on solid dielectric DC cable

open access: yes, 2009
It is well known that existence and accumulation of space charge within the insulating material poses threat to the reliability in the operation of dc power cables. When the cables are loaded under high voltage direct current (HVDC), temperature gradient
Choo, Wilson   +2 more
core   +1 more source