Results 11 to 20 of about 1,722,896 (320)
An improved modulation method is proposed for two parallel three-level interleaved rectifiers to reduce current harmonics and high-frequency zero-sequence circulating current, which uses sinusoidal pulse width modulation.
Yanfeng Li +3 more
doaj +1 more source
Through the analysis of the recovery inrush current generated by the external fault removal of the converter transformer, it is pointed out that the zero-sequence current caused by the recovery inrush may result in the saturation of the neutral current ...
Tao Zheng +4 more
doaj +1 more source
Single phase‐earth faults are the most frequent faults likely to occur but hard to identify in distribution system, especially in a neutral un‐effectively grounded system.
Hua Zhang +7 more
doaj +1 more source
Network-centric technologies for control of three-phase network operation modes [PDF]
Purpose. The development of the control system for three-phase network is based on intelligent technologies of network-centric control of heterogeneous objects.
Gapon, D. A. +5 more
core +7 more sources
Analytical Optimal Currents for Multiphase PMSMs Under Fault Conditions and Saturation [PDF]
An original analytical expression is presented in this paper to obtain optimal currents minimizing the copper losses of a multi-phase Permanent Magnet Synchronous Motor (PMSM) under fault conditions.
FLIELLER, Damien +3 more
core +5 more sources
Frequency Response Testing of Zero-Sequence Current Transformers for Mining Ground Fault Protection Relays [PDF]
In Polish coal mining, medium voltage power distribution networks operate with an insulated neutral point. Zero-sequence current transformers are the basic sensors that generate input signals for earth-fault protection relays.
Krzysztof Kuliński, Adam Heyduk
doaj +1 more source
Analysis and Suppression of Zero Sequence Circulating Current in Open Winding PMSM Drives With Common DC Bus [PDF]
In this paper, the zero sequence circulating current in open winding permanent magnet synchronous machine (OW-PMSM) drives with common dc bus is systematically analyzed for the first time.
Odavic, M., Zhan, H., Zhu, Z.Q.
core +1 more source
In microgrids, paralleled converters can increase the system capacity and conversion efficiency but also generate zero-sequence circulating current, which will distort the AC-side current and increase power losses.
Zhao Han +3 more
doaj +1 more source
In order to use the existing hardware sources to improve the line selection performance of single-phase grounding fault of small resistance grounding systems, a method for line selection of single-phase grounding fault based on the global steady-state ...
LIU Jian +4 more
doaj +1 more source
At present, zero-sequence current protection is generally used as the main protection for single-phase ground faults in resistance-grounded inverter power stations.
Qian He +5 more
semanticscholar +1 more source