Zero-Sequence Current Distribution Along Transmission Lines
IEEE Transactions on Power Apparatus and Systems, 1969The zero-sequence current distribution among ground wires and the ground-return path of overhead transmission lines is subject to change in the vicinity of a ground fault and the feeding point. This paper introduces the concepts used in connection with the end-effect phenomena of transmission lines and describes the necessity for solving the end-effect
openaire +1 more source
Diagnosis of bearing fault in induction motor by zero sequence current
2017 International Conference on Innovative Research In Electrical Sciences (IICIRES), 2017Fault detections are essential for unexpected failures of the electrical motors. Early detection and faults diagnosis leads to effective operations. This paper deals a diagnosis of faults in three phase induction motor by means of zero-sequence stator current spectrum. The simulation and experimental setup are designed under bearing faults.
P. Kripakaran, B. Rami Reddy
openaire +1 more source
The Research on the Zero Sequence Circulating Current Suppression in Parallel Inverters
2012 Asia-Pacific Power and Energy Engineering Conference, 2012That inverters work in direct parallel would increase the reliability and capacity, and also reduce the cost and volume for tidal current generation system, but the zero sequence circulating current will be generated. The state model of the parallel connected inverters is constructed in synchronous rotating coordinates, the mechanism of circulating ...
Yaohua Luo +4 more
openaire +1 more source
Research on zero-sequence current calculation method for VSC and circulation current of parallel VSC
2017 2nd International Conference on Power and Renewable Energy (ICPRE), 2017Renewable energy usually adopts flexible grid connection technology which based on three-phase voltage source converter (VSC) and droop control to connect with the distribution. Zero-sequence current of three-phase VSC has influence on on-state loss current and zero-sequence circulating current.
Di Wu +5 more
openaire +1 more source
Optimal Design of Flux Coupling Differential Zero-Sequence Current Transformer
2020 4th International Conference on Power and Energy Engineering (ICPEE), 2020With the operation of neutral point grounding syste m with small resistance, zero sequence current transformer ha s the problems of huge volume and insufficient accuracy in pra ctical engineering. Using flux constrained zero sequence curren t transformer can solve the problem of crossing three-phase ca ble and reduce the volume of equipment. At present,
Weining Wu +4 more
openaire +1 more source
IEEE Transactions on Applied Superconductivity, 2014
A 500 kV saturated iron-core superconductive fault current limiter (SISFCL) has been designed to be installed in an extra high voltage (EHV) transmission system in southern China. We carried out studies on compatibility and coordination problems in the application of this kind of device in an EHV network.
null Bin Li +5 more
openaire +1 more source
A 500 kV saturated iron-core superconductive fault current limiter (SISFCL) has been designed to be installed in an extra high voltage (EHV) transmission system in southern China. We carried out studies on compatibility and coordination problems in the application of this kind of device in an EHV network.
null Bin Li +5 more
openaire +1 more source
IEEE Transactions on Industrial Electronics, 2017
A zero-sequence circulating current (ZSCC) is typically generated among the multiparallel converters that share the common dc link and ac side without isolated transformers under the space vector modulation (SVM), due to the injected third-order zero-sequence voltage (ZSV).
Rongwu Zhu +3 more
openaire +1 more source
A zero-sequence circulating current (ZSCC) is typically generated among the multiparallel converters that share the common dc link and ac side without isolated transformers under the space vector modulation (SVM), due to the injected third-order zero-sequence voltage (ZSV).
Rongwu Zhu +3 more
openaire +1 more source
Single phase to ground fault location based on phase of zero-sequence current
2013 IEEE International Conference on Information and Automation (ICIA), 2013With the continuous development of society and the improvement of people's life, people are increasingly concerning about the safe operation of the power grid, and single phase to ground fault of distribution networks is one of the problems. Because more branch of distribution networks and complex structure, the traditional methods can't achieve ...
Jinjie Li +3 more
openaire +2 more sources
2015 5th International Conference on Electric Utility Deregulation and Restructuring and Power Technologies (DRPT), 2015
It is difficult to select the fault line due to the weak current when the single-phase grounding fault occurs in the resonant grounding system. A new method based on correlation between zero-sequence voltage in bus and zero-sequence current in feeders is proposed in this paper.
Yunkun Xiang +4 more
openaire +1 more source
It is difficult to select the fault line due to the weak current when the single-phase grounding fault occurs in the resonant grounding system. A new method based on correlation between zero-sequence voltage in bus and zero-sequence current in feeders is proposed in this paper.
Yunkun Xiang +4 more
openaire +1 more source