Results 11 to 20 of about 266,614 (289)
Control Strategies for Open-End Winding Drives Operating in the Flux-Weakening Region [PDF]
This paper presents and compares control strategies for three-phase open-end winding drives operating in the flux-weakening region. A six-leg inverter with a single dc-link is associated with the machine in order to use a single energy source.
BRUYERE, Antoine +4 more
core +5 more sources
To explore the clustered voltage balancing mechanism of the cascaded H-bridge static synchronous compensator (STATCOM), this paper analyzes the causes of unbalanced clustered voltage. The negative-sequence current caused by the compensation of unbalanced
Yu Jin +4 more
doaj +1 more source
The open-winding driving system can improve power density and torque output capacity of the motor. However, the open-winding topology with a common direct current (DC) power supply provides a path for the zero-sequence current, which contributes to the ...
Qing Lu +3 more
doaj +1 more source
Influence of grid configuration on current conducting behaviour in PV installations [PDF]
On the roof of an industrial site a 385 kWp PhotoVoltaic installation is operational. When production of this system reaches 60% of the installed power, the circuit breaker trips.
Debruyne, Colin +3 more
core +2 more sources
We developed an International Electrotechnical Commission (IEC) 61850-based centralized protection scheme to prevent single line-to-ground (SLG) faults in the feeders and busbars of ungrounded distribution systems.
Soon-Ryul Nam +4 more
doaj +1 more source
Zero phase sequence voltage injection for the alternate arm converter [PDF]
The Alternate Arm Converter (AAC) is a voltage source converter being developed as an alternative to the Modular Multilevel Converter (MMC) for HVDC power transmission and reactive power compensation.
Dyke, KJ +4 more
core +1 more source
Analysis and Suppression of Zero Sequence Circulating Current in Open Winding PMSM Drives With Common DC Bus [PDF]
In this paper, the zero sequence circulating current in open winding permanent magnet synchronous machine (OW-PMSM) drives with common dc bus is systematically analyzed for the first time.
Odavic, M., Zhan, H., Zhu, Z.Q.
core +1 more source
An individual sequencing control strategy for three-phase four-leg inverter under unbalanced loads
Under the influence of the unbalanced load, the negative and zero sequence components in the output voltage of the three-phase four-leg voltage source inverter(TPFL-VSI) will cause asymmetry voltage.
Hanzhou Jiang, Huan Pan, Bin Shang
doaj +1 more source
Principle of Flexible Ground-Fault Arc Suppression Device Based on Zero-Sequence Voltage Regulation
Single-line-to-ground (SLG) fault arcs cause the intermittent over-voltages, leading to short circuits within large-scale area. In this paper, a flexible arc suppression device is proposed, which adopts a zigzag grounding transformer, multi-terminal ...
Bishuang Fan +6 more
doaj +1 more source
IGBT-SiC dual fed open end winding PMSM drive [PDF]
This paper proposes a dual fed common dc link inverter Open End Winding-Permanent Magnet Synchronous Motor (OEW-PMSM) Drive. In order to increase the system efficiency a dual technology converter is used, with one inverter composed of standard IGBT ...
Cox, Tom +4 more
core +1 more source

