With the increasing applications of grid-connected voltage source converters, it is important to analyze the impedance characteristic of the grid-connected system to implement the stability analysis of the grid connection operation.
Heng Nian +5 more
doaj +3 more sources
Through the analysis of the recovery inrush current generated by the external fault removal of the converter transformer, it is pointed out that the zero-sequence current caused by the recovery inrush may result in the saturation of the neutral current ...
Tao Zheng +4 more
doaj +3 more sources
Model development for the analysis of reducing voltage asymmetry methods in power supply systems
THE PURPOSE. To consider the issues of ensuring the quality of electricity in power supply systems. Show that the quality of electrical energy during the operation of power supply systems in certain cases may be violated, including due to uneven loading ...
V. I. Biryulin, D. V. Kudelina
doaj +1 more source
A three-phase ac-dc converter with high-frequency isolation can be realized as a phase-modular system by using three single-phase Power Factor Correction (PFC) rectifier modules with isolated dc-dc converter output stages, which advantageously allows to ...
Thomas Langbauer +6 more
doaj +1 more source
Realizing an isolated three-phase Power Factor Correction (PFC) ac-dc converter as a phase-modular system, i.e., by star-connecting three single-phase PFC rectifier front-ends with individual isolated dc-dc converter stages generating a common dc output ...
David Menzi +3 more
doaj +1 more source
A Power Ripple Compensator for DC Nanogrids via a Solid-State Converter
This paper presents a method for improving the reliability of DC nanogrids by decreasing the input capacitance requirement. The nanogrid DC bus capacitance requirement is reduced by utilizing the zero-sequence operation mode of the solid state converter (
Ahmad Khan +3 more
doaj +1 more source
Introduction. A significant proportion of earth faults in medium voltage networks represents a short-lived and transient process. Problem. In such cases, earth fault protection that responds to steady-state current and voltage is not able to operate ...
V. F. Syvokobylenko, V. A. Lysenko
doaj +1 more source
Restraint Scheme of Transformer Zero Sequence Differential Protection Based on Tanimoto Similarity
As one of the important transformer protections, zero sequence differential protection has the advantages of high sensitivity and strong anti-interference ability.
Jia ZHU +5 more
doaj +1 more source
In some key areas, fault-tolerant control is usually needed in order to enable the motor to operate continuously in fault mode. Given that it is difficult to detect the zero-sequence current of the open winding permanent magnet synchronous motor after ...
Kangfei Lv, Xinwei Dong, Cong Zhu
doaj +1 more source
The structure of maximal zero-sum free Sequences [PDF]
Let n be an integer, and consider finite sequences of elements of the group Z/nZ x Z/nZ. Such a sequence is called zero-sum free, if no subsequence has sum zero.
Bhowmik, Gautami +2 more
core +3 more sources