Results 1 to 10 of about 4,776 (201)
Reliability Evaluation Method of Urban Distribution Network Power Supply Considering Automatic Partitioning of Distribution Network [PDF]
[Introduction] Under the current situation of increasing automation level of distribution network, in order to solve the problem that the influence of distribution automation is not considered in traditional distribution network power supply reliability ...
Wei LIAO, Wenfeng YANG, Zhou SHU
core +1 more source
针对使用广泛的500 kV架空输电线路,分别研究了在轻、中、重冰区,由断线及不均匀覆冰引起的导线张力对输电杆塔安全性和经济性的影响。研究表明:导线张力增加0~20%,若保持杆塔杆件规格不变,悬垂塔的超限杆件比例为0~51%,耐张塔的超限杆件比例为0~4%;若增大杆塔杆件规格以保证安全,悬垂塔的塔重增加0~28%,耐张塔的塔重增加0~5%;覆冰越厚,由断线引起的导线张力对杆塔影响越小,由不均匀覆冰引起的导线张力对杆塔影响越大;导线张力主要影响悬垂塔横担上、下平面交叉材、塔身主斜材等杆塔杆件。因此 ...
张林枫 +6 more
core +1 more source
目的 本国际临床指南由欧洲残疾儿童学会(the European Academy of Childhood Disability,EACD)牵头制定,旨在解决发育性协调障碍(developmental coordination disorder,DCD)的定义、诊断、评估、干预以及与社会心理方面的临床应用关键问题。 方法 本指南针对五个领域的关键问题,通过文献综述和专家团队的正式讨论达成共识。为保证指南的循证基础,以“机制”、“评估”和“干预”为检索词, 对2012年更新以来提出的最新建议以及新增的“社会心理问题”和“青少年/成人”为检索词进行检索。根据牛津大学循证医学中心证据等级 (证据水平 [level of evidence, LOE]1–4) 将结果进行分类,最终转化为指南建议。并由国际 ...
Jing Hua +6 more
wiley +1 more source
为研究雷击配电线路附近建筑物时,土壤散流引发配电线路雷电过电压及防护效果,采用专业防雷计算软件CDEGS建立建筑接地网及临近配电线路雷电过电压仿真模型,分析了配电线路与临近建筑接地网间距、土壤电阻率、雷电流幅值和配电线路接地网长度对配电线路上雷电过电压的影响,并仿真验证了引流法和绝缘间隔法的防护效果。研究结果表明:配电线路电位随间距的增大而减小,随土壤电阻率和雷电流幅值的增大而线性增大,受配电线路接地网长度影响不大;引流法和绝缘间隔法能有效地降低配电线路接地体上电位,水平外延法引流降压效果更好 ...
冯守信 +5 more
doaj
Discussion on the Fire Fighting Equipment Power Cable and Application [PDF]
通过综述消防设备供电线缆的术语、分类及规范对消防设备供电线缆的选用要求,分析了当前消防设备供电线缆从术语、消防线路产品及设计选用等方面存在的问题,提出应规范并丰富消防设备供电线缆的术语,科学地划分产品类别,并结合产品标准及检验标准,将满足消防设备在火灾事故时连续供电要求的线缆应用在建筑防火工程中去,已达到减少火灾危害,保护人员和财产安全的目的。Through reviewing the firefighting equipment power cable terminology, classi ...
任耀辉
core +1 more source
Power-Line Extraction Method for UAV Point Cloud Based on Region Growing Algorithm [PDF]
[Introduction] Since the power line has the characteristics of long transmission distance and a complex spatial environment, the UAV LiDAR point cloud technology can completely and efficiently obtain the geometric information of the power line and its ...
Wei WU, Xingyi LI, Zhiyao ZHAO
core +1 more source
大容量试验是检验电力装备性能,保障装备安全可靠运行的重要环节。现有的大容量试验回路主要依靠人工操作,存在流程复杂、效率低且易出错的问题。针对大容量试验回路智能化控制的难题,研究建立了冲击发电机单电机短路模型和双电机并联短路模型,分析了发电机短路特性,结合典型大容量试验回路设计了一键顺控方案,提出试验回路一键顺控操作流程。通过对发电机短路模型和大容量试验回路系统的仿真 ...
吴益飞 +7 more
core +1 more source
适用于直流配电网故障选线的电力电子变压器分步闭锁方案 [PDF]
级联H桥型电力电子变压器(power electronic transformer with cascaded H-bridge,CHB-PET)是柔性变电站的重要组成设备之一,在直流配电网中具有重要作用。当CHB-PET低压直流侧发生双极短路故障后,故障电流上升速度快且幅值较高,易导致电力电子器件迅速闭锁,使低压直流电网保护难以准确获取故障信息。针对CHB-PET低压侧多分支直流配电网,提出一种基于PET分步闭锁的故障穿越策略。当检测到PET低压侧直流系统故障后 ...
于弘洋 +5 more
core +1 more source
雷击感应过电压是造成有源配电系统故障的主要原因,研究分布式光伏系统接入配电线路后感应过电压特性具有重要意义。在ATP中搭建了分布式光伏系统接入10 kV配电线路感应过电压计算模型,计算了雷击有源配电线路不同位置时,配电线路侧和光伏侧感应过电压的变化规律,并提出了相应的防雷配置优化策略。结果表明:当雷击线路杆塔附近地面时,线路上产生的感应过电压会影响光伏系统稳定运行;当雷击光伏阵列金属边框时,不会对配电线路造成影响;在并网变压器高低压侧分别安装避雷器和SPD时 ...
柴辰 +4 more
doaj
短路故障和断线故障是配电网常见的线路故障,对配电网安全稳定运行有重要影响。本研究以不接地配电系统为对象,提出在线路绝缘子内部集成陶瓷电容,通过电容分压检测配电网线路故障的暂态电压信号,进而实现配电线路故障检测的新方法。采用PSCAD/EMTDC软件建立了短路故障和断线故障情况下配电系统的仿真模型,研究了典型故障工况下绝缘子内置电容分压器监测的线路电压特征。结果表明:对于低阻和中阻接地故障,线路故障相电压迅速减小至稳定值,健全线路对应相的电压欠阻尼振荡衰减至稳定值,故障线路与健全线路的暂态高频信号特征明显;
黄继盛, 刘红文, 唐钊, 张春丽
doaj