Results 71 to 80 of about 94,612 (306)

Comparison of Bioelectrical Impedance Analysis and Dual-Energy X-Ray Absorptiometry for Estimating Bone Mineral Content

open access: yes, 2018
The purpose of this study was to validate single-frequency hand-to-foot bioelectrical impedance analysis (HFBIA) for estimating bone mineral content (BMC) using dual-energy X-ray absorptiometry as the criterion measure in healthy men and women aged 18–40
Michael R. Esco   +7 more
core   +1 more source

Artificial intelligence across the continuum of care for the aging musculoskeletal patient: From longitudinal phenotyping to personalized surgery and recovery monitoring

open access: yesKnee Surgery, Sports Traumatology, Arthroscopy, EarlyView.
Abstract Musculoskeletal care is being reshaped by population aging, multimorbidity, frailty, osteoporosis, sarcopenia, polypharmacy and increasing vulnerability to postoperative loss of independence. Artificial intelligence (AI) has entered orthopaedic research, but its clinical translation remains constrained. Many models address isolated diagnostic,
Felix C. Oettl   +8 more
wiley   +1 more source

Artifacts affecting dual-energy X-ray absorptiometry and bone mineral density measurements: a case report and review of the literature

open access: yesJournal of Medical Case Reports
Introduction It is important to recognize artifacts of dual-energy X-ray absorptiometry because they may alter bone mineral density measurements. To prevent erroneous decisions and misdiagnosis regarding treatment and follow-up, bone mineral density ...
Kevin White   +3 more
doaj   +1 more source

ANALYSIS OF DUAL-ENERGY X-RAY ABSORPTIOMETRY IMAGES USING COMPUTER VISION METHODS [PDF]

open access: yesTrakia Journal of Sciences, 2020
PURPOSE: Dual-energy x-ray absorptiometry (DXA) is the “golden standard” for diagnosing osteoporosis. Its analyzing algorithm (software) makes it possible to distinguish the bone from the soft tissue.
10.15547/tjs.2020.s.01.020
doaj  

Automatic determination of airborne dust and lead contents by x-ray Differential Absorptiometry

open access: yes, 1992
Automatic instrument based on Xray differential absorptiometry for determination on lead content in airborne ...
FALCUCCI C   +4 more
core  

Imaging Method: Dual-Energy X-Ray Absorptiometry

open access: yes, 2017
Dual energy X-ray absorptiometry is used for the assessment of physique traits of athletes. Given the use of X-rays and thus exposure to radiation, specific training by a suitably accredited national organisation is required before dual energy X-ray ...
Alisa Nana   +5 more
core   +1 more source

Early Circulatory and Red Blood Cell Aggregation Changes During a Short‐Term Bone‐Specific Exercise Program in Community‐Dwelling Older Women: An Exploratory Pilot Study

open access: yesMedicine Advances, EarlyView.
A 6‐week bone‐specific exercise program in community‐dwelling older women was associated with increased peripheral blood flow and improved red blood cell aggregation. In contrast, calcaneal quantitative ultrasound showed no significant change in the speed of sound.
Shiho Kurosaka   +3 more
wiley   +1 more source

Lean mass reference curves in adolescents using dual-energy x-ray absorptiometry (DXA).

open access: yesPLoS ONE, 2020
The body composition phenotype of low lean mass (LM) has been associated with metabolic disorders and impaired physical functioning in the pediatric population.
Wagner Luis Ripka   +5 more
doaj   +1 more source

Correlation coefficients between mean differences and mean scores for each surrogate assessment against dual emission X-ray absorptiometry.

open access: yes, 2019
Correlation coefficients between mean differences and mean scores for each surrogate assessment against dual emission X-ray absorptiometry.
You Fu (6490688)   +2 more
core   +1 more source

Comparison of six nutritional screening tool‐based Global Leadership Initiative on Malnutrition criteria models for predicting activities of daily living in older patients with subacute stroke: A single‐center retrospective cohort study

open access: yesNutrition in Clinical Practice, EarlyView.
Abstract Background The Global Leadership Initiative on Malnutrition (GLIM) recommends a two‐step diagnostic process consisting of initial screening for malnutrition risk followed by diagnostic assessment. We evaluated the association between GLIM‐defined malnutrition identified using six alternative first‐step screening tools and Functional ...
Shinnosuke Ishida   +4 more
wiley   +1 more source