Results 1 to 10 of about 31,428 (130)
Analysis of Arc Re-Ignition in Vacuum Interrupter-Based HVdc Circuit Breakers
The protection of HVdc systems has long been challenged by the absence of natural current zero-crossing, typically addressed using L-C branches. However, the phenomenon of multiple arc reignitions in vacuum interrupter (VI) based HVdc circuit breakers ...
Tamer Eliyan +3 more
doaj +2 more sources
The new horizons for HVDC systems and their applications has intensified the research in HVDC protection systems. The HVDC circuit breakers (CB) has been the center of the protection systems with vacuum interrupters (VIs) showcasing a great potential for
Tamer Eliyan +3 more
doaj +2 more sources
To explore the factors affecting the arc extinction performance of the self-disengaging lightning protection device, a numerical simulation model of arc extinction process of the device based on magneto-hydrodynamic theory is established in this paper ...
XIE Congzhen +5 more
doaj +1 more source
Overvoltages during switching operations of vacuum switching devices [PDF]
This paper presents the results of experimental studies of voltage phenomena in the switching operations of vacuum switching devices made by various manufacturers in several different configurations of 6 kV, 10 kV, 20 kV and 35 kV networks.
Vukelja Petar +3 more
doaj +1 more source
Research on the Effect of an Air-Blown Interrupting Gap to Reduce the Rate of Lightning Tripping
The air-blown interrupting gap protection method is a self-energy interrupting method based on the concept of suppressing arc building by frequency continuation.
Hao Li +4 more
doaj +1 more source
During the fault current breaking process of a mechanical direct current vacuum circuit breaker (DC VCB) with double-break (DB), the mechanism’s dispersion can result in a gap difference between the two breaks. A DB DC VCB breaking experiment platform is
Chongyang Huang +5 more
doaj +1 more source
Due to the extreme thermal conditions and short lifetimes, experimental exploration of cathode spots in vacuum arcs is very difficult. The intensive heat in the cathode spot is believed to be generated by ion bombardment and by Joule heating.
Johann Peter Mogeritsch +4 more
doaj +1 more source
The article presents the results of research in the field of limiting the effects of overvoltages and improving the conditions for the self-extinguishing of transient faults in medium voltage networks with earth fault current compensation. The aim of the
Jerzy Andruszkiewicz +4 more
doaj +1 more source
Characteristics of the flame flashback in a dual-mode scramjet combustor by the gliding arc plasma
A multi-channel gliding arc (MCGA) plasma with an average power of 6000 W is utilized to control the flame flashback in a dual-mode scramjet combustor with a cavity flameholder.
Rong Feng +8 more
doaj +1 more source
Re-igniting the afterglow plasma column of an AC powered gliding arc discharge in atmospheric-pressure air [PDF]
The stability and re-ignition characteristics of the plasma column of an alternating current (AC) powered gliding arc discharge operating in atmospheric-pressure air were investigated for better plasma-mode controlling and optimized applications. By modulating the AC power supply and the air flow field, the states of afterglow plasma column were varied.
Chengdong Kong +5 more
openaire +2 more sources