Results 91 to 100 of about 2,445 (130)
Some of the next articles are maybe not open access.
ESTUDO DA DINÂMICA DE ATUADORES HIDRÁULICOS COM ATRITO NÃO LINEAR
Conferência Brasileira de Dinâmica, Controle e Aplicações, 20111 DETEC/UNIJUI Campus Panambi, Caixa Postal 121, CEP 98280-000, Panambi RS, Brasil, marcia_fgo@hotmail.com 2 DETEC/UNIJUI Campus Panambi, Caixa Postal 121, CEP 98280-000, Panambi RS, Brasil, valdiero@unijui.edu.br 3 DETEC/UNIJUI Campus Panambi, Caixa Postal 121, CEP 98280-000, Panambi RS, rasia@unijui.edu.br 4 DETEC/UNIJUI Campus Panambi, Caixa Postal ...
Marcia Fritsch Gonçalves +5 more
openaire +1 more source
Controle Tolerante a Falhas: Reconfiguração com Atuador Virtual Adaptativo
Procedings do XXII Congresso Brasileiro de Automática, 2022null Mariella Maia Quadros +1 more
openaire +1 more source
ANÁLISE DO CHAVEAMENTO ENTRE VÁLVULAS PARA ATUADOR HIDRÁULICO DIGITAL (DHA)
Procedings do XXII Congresso Brasileiro de Autom�tica, 2018A baixa relacao peso/potencia e rapida resposta dinâmica sao caracteristicas que fazem com que a hidraulica de potencia seja opcao tecnologica para diversas aplicacoes. Em contrapartida, a eficiencia energetica e relativamente baixa, princi-palmente pelo controle da potencia hidraulica de maneira resistiva por orificios de controle.
null Ivan J. Mantovani +2 more
openaire +1 more source
2015
In this paper we addressed the issue of wireless sensors for low cost and consumption for measuring water content in cod during its drying process in greenhouses. These sensors gain an increasingly important role in the food industry, particularly in the manufacturing industry of cod, where the optimization of curing time for cod has a huge economic ...
openaire +1 more source
In this paper we addressed the issue of wireless sensors for low cost and consumption for measuring water content in cod during its drying process in greenhouses. These sensors gain an increasingly important role in the food industry, particularly in the manufacturing industry of cod, where the optimization of curing time for cod has a huge economic ...
openaire +1 more source
Acoplamento de atuadores eletromecânicos a válvulas de esquentadores
2018The heaters currently produced by Bosch Thermotechnology rely on valves based on solenoid actuators for regulating the fuel flow. Each actuator is characterized by parameters that ensure the correct functioning of the devices, namely with regard to gas flows and pressure drops through the valves.
openaire +1 more source
Controladores Chaveados em Sistemas PWA Implícitos com Atuadores Saturantes Assimétricos
Proceedings do Congresso Brasileiro de AutomáticaThis work deals with the exponential stabilization of discrete-time and piecewise related systems, using an implicit representation. In particular, the case of saturating actuators with asymmetric saturation limits is treated. The contributions of this proposal are i) a methodology that involves the alternation of nonlinear (via differential evolution ...
null Heros C. Soares +3 more
openaire +1 more source
Estudo comparativo de atuadores capacitivos para implantes ativos
2018For the development of active instrumented implants equipped with the ability to control their integration with the surrounding bone tissues, it is necessary to analyze the behavior of therapeutic actuation systems. Previous studies have observed the osteogenic potential of electromagnetic stimulation using capacitive stimulators.
openaire +1 more source
Estabilidade global de sistemas lineares positivos sujeitos a saturação nos atuadores
Proceedings do Simpósio Brasileiro de Sistemas Elétricos, 2023null Amanda Spagolla +4 more
openaire +1 more source
Controle Extremal Multivariável com Atuadores Saturantes
Anais do XVII Simpósio Brasileiro de Automação Inteligente (SBAI 2025) e XI Simpósio Brasileiro de Sistemas Elétricos (SBSE 2025)Enzo Ferreira Tomaz Silva +2 more
openaire +1 more source
Modelo Numérico de Controle de Vibrações Self-Sensing Utilizando Atuadores Eletromagnéticos
2023Aldemir Ap Cavallini Jr
exaly

