Results 21 to 30 of about 52,179 (162)

Damage Detection of Axially Loaded Beam: A Frequency-Based Method [PDF]

open access: yesCivil Engineering Infrastructures Journal, 2016
The present study utilizes an analytical method to formulate the three lowest modal frequencies of axially-loaded notched beam through both crack location and load level in a specific format that can be used in existing frequency-based crack ...
Omid Rezaifar   +1 more
doaj   +1 more source

Influence of Restorative Material on the Distribution of Loads to the Bone in Hybrid Abutment Crowns—In Vitro Study

open access: yesMedicina, 2023
Background: The objective of this study was to evaluate the load transmitted to the peri-implant bone by seven different restorative materials in single-unit rehabilitations with morse taper implants using a strain gauge.
Rafael Garcia Martins   +4 more
doaj   +1 more source

Experimental study on the crack resistance of steel-nanometre hybrid fibre concrete [PDF]

open access: yesE3S Web of Conferences, 2022
To investigate the effects of steel fibre and nanometre fibre on the cracking of reinforced concrete, the cracking resistance of steel fibre reinforced concrete, nanometre fibre reinforced concrete, and hybrid fibre reinforced concrete with different ...
Wu Hailin, Mi Zijia, Pei Ziqiang
doaj   +1 more source

THE EFFECT OF VARIATION CONCRETE CUBE OF AXIAL LOAD ON ULTRASONIC PULSE VELOCITY TRANSMITTER

open access: yesJournal of the Civil Engineering Forum, 2015
Nowadays, Non Destructive Tests have been applied in some quality evaluation of existing concretes on site. One of the Non Destructive Test (NDT) methods is the application of the Ultrasonic Pulse Velocity (UPV) method. In general, utilizations of UPV as
Faqih Ma’arif   +2 more
doaj   +1 more source

NEW GENERATION NAIL VS. PLATE IN THE TREATMENT OF UNSTABLE INTERTROCHANTERIC FEMORAL FRACTURE [PDF]

open access: yesActa Ortopédica Brasileira, 2020
Objective: To compare antirotator proximal femoral nail (A-PFN) with antirotator dynamic hip screw (A-DHS). Methods: Fourteen proximal femur models with type 31/A2 fracture, according to the AO Foundation/Orthopaedic Trauma Association (AO/OTA ...
BURAK OZTURAN   +3 more
doaj   +1 more source

Safety assessment on girth welds of large-diameter X80 pipelines in water network area

open access: yesYou-qi chuyun, 2023
As the soil in the water network area is soft and has large water content, it is very easy to settle, which applies an axial load to the pipeline, and the girth weld under the action of tensile load has a higher risk of failure.
Yuqing LIU   +5 more
doaj   +1 more source

Control of the axial offset in a nuclear reactor at power maneuvering

open access: yesTrudy Odesskogo Politehničeskogo Universiteta, 2014
High reliability and security of power unit are basic requirements when the power unit maneuvering mode operation. The reactor stability under disturbances both at steady load and maneuvering load embodies the guarantees of power unit safe and reliable ...
Maksim V. Maksimov   +2 more
doaj   +1 more source

Study on Impact Load and Head Cap Load Reduction Performance of Vehicle Entering Water at High Speed

open access: yesJournal of Marine Science and Engineering, 2022
Aiming at the problem of high-speed entry of vehicles with a diameter of 200 mm, a numerical model of high-speed entry of vehicles is established based on the arbitrary Lagrange–Euler (ALE) algorithm, and the numerical simulation of high-speed entry of ...
Hairui Zhao   +3 more
doaj   +1 more source

Member-Level Redundancy of Built-Up Steel Axially Loaded Members

open access: yes, 2019
Full-scale fracture tests were completed determining that mechanically-fastened steel built-up axially-loaded tension members are resistant to running fracture when a single component suddenly fractures. This characteristic of built-up member is referred to as Cross-Boundary Fracture Resistance (CBFR).
Lloyd, Jason B   +3 more
openaire   +4 more sources

The effect of multiplanar loading on the intradiscal pressure of the whole human spine: systematic review and meta-analysis [PDF]

open access: yesEuropean Cells & Materials, 2021
For spinal load and muscle force estimation as well as for numerical model and experimental setup validation, data on human intradiscal pressure are essential.
C Liebsch, HJ Wilke
doaj   +1 more source

Home - About - Disclaimer - Privacy