Results 161 to 170 of about 33,001 (294)

Bicuspid Aortic Valve Disease: Classifications, Treatments, and Emerging Transcatheter Paradigms

open access: yesStructural Heart
Bicuspid aortic valve (BAV) is a common congenital valvular malformation, which may lead to early aortic valve disease and bicuspid-associated aortopathy. A novel BAV classification system was recently proposed to coincide with transcatheter aortic valve
Ankur Kalra, MD   +11 more
doaj   +1 more source

Advances in cardiac devices and bioelectronics augmented with artificial intelligence

open access: yesThe Journal of Physiology, EarlyView.
Abstract figure legend Interfaces between the human heart, diagnostic bioelectronics, artificial intelligence, and clinical care. From left to right: Human heart and biosensor interface; representative waveforms of common diagnostic bioelectronic sensing modalities.
Charles Stark   +3 more
wiley   +1 more source

Elastin integrity in bicuspid valve-associated aortopathy is associated with altered biomechanical properties and influenced by age. [PDF]

open access: yesAnn Cardiothorac Surg, 2022
Nightingale M   +7 more
europepmc   +1 more source

AP2M1 Is a Candidate Gene for Microcephaly and Intellectual Disability in 3q27.1 Deletions

open access: yesAmerican Journal of Medical Genetics Part A, Volume 197, Issue 11, November 2025.
ABSTRACT Deletions of the 3q26.33q27.2 region appear to correlate with a distinct phenotype, although there are few reported cases. Here, we present seven previously unreported individuals carrying de novo 3q27 deletions (under 5 Mb), which include the AP2M1 (adaptor‐related protein complex 2, mu‐1 subunit) gene and summarize data from 12 previously ...
Russell Gear   +16 more
wiley   +1 more source

Use of the snare technique for crossing a severely calcified bicuspid valve and horizontal aorta. [PDF]

open access: yesAnatol J Cardiol, 2022
Oba Y   +5 more
europepmc   +1 more source

Comparative evaluation of coronary disease burden: bicuspid valve disease is not atheroprotective. [PDF]

open access: yesOpen Heart, 2021
Dolmaci OB   +5 more
europepmc   +1 more source

Lessons Learned From the ACURATE IDE Trial for Transcatheter Aortic Valve Replacement

open access: yesCatheterization and Cardiovascular Interventions, Volume 106, Issue 4, Page 2554-2560, October 1, 2025.
ABSTRACT The recent voluntary withdrawal of the ACURATE neo2 transcatheter aortic valve replacement device by Boston Scientific offers a compelling case study in the complex interplay of device design, clinical evidence, regulatory requirements, and market dynamics in modern structural heart interventions.
Arturo Giordano   +4 more
wiley   +1 more source

Transaortic Transcatheter Aortic Valve Replacement With Bicuspid Aortic Valve Stenosis and Circumflex Aortic Arch

open access: yesClinical Case Reports, Volume 13, Issue 10, October 2025.
Computed tomography images of (A) coronal (B) axial and (C) 3‐dimensional reconstruction of the circumflex aortic aorta, and (D) coronal section of head and neck. Anterior‐posterior fluoroscopy images of guidewire and catheters via transfemoral access (E, F). ABSTRACT Circumflex aortic arch is a rare congenital anomaly.
Merrina Lan   +3 more
wiley   +1 more source

Home - About - Disclaimer - Privacy