Results 41 to 50 of about 422 (143)
Abstract This research investigates the intricate relationship between load variations, environmental conditions, and the resultant stray current generation within DC railway systems. A scaled‐down single‐viaduct model was employed to establish a controlled experimental environment for real‐time monitoring of voltage differentials between the railway ...
Tawat Chuchit +3 more
wiley +1 more source
Electromagnetic Field Calculation of Transformer Station 400/110 kV Ernestinovo Using CDEGS Software
This paper presents calculations of the electric and magnetic fields of complex busbars, transformers and transmission line structures at the transmission power station 400/110 kV Ernestinovo. By constructing and bringing the TS 400/110 kV Ernestinovo in operation, it was expected that electric and magnetic fields would arise within and outside the ...
Marić, Predrag +2 more
openaire +3 more sources
This paper proposes a two‐stage coordination approach that integrates price‐based demand response (PBDR) and energy storage systems, encompassing Battery Energy Storage Systems (BESS) and Compressed Air Energy Storage (CAES). ABSTRACT Peak load management is a pivotal aspect of power generation and distribution, representing one of the primary ...
Mohsen Masoumi‐Anaraki +2 more
wiley +1 more source
Two‐Layer Optimal Electricity Trading Method for Distribution Networks with Multi‐MG
To enhance the operational benefits of distribution networks and microgrids while reducing microgrid energy costs, this paper proposes a distributed trading strategy for microgrids based on a leader–follower game. First, a multi‐objective two‐layer optimization trading model for distribution network (DN)‐microgrid (MG) interaction is established based ...
Chen Zhe +4 more
wiley +1 more source
Over the course of the study, heavy metals (Cr, Cu, Cd, Fe, Zn and Pb) were analysed using Flame atomic absorption spectrophotometer. The assessed mean concentrations of heavy metals follow the trend: Fe > Pb > Zn > Cr > Cu > Cd. A moderate seasonal variation was found among the sampling sites.
Afsana Kamal +5 more
wiley +1 more source
A full‐size steel‐framed residential test platform was constructed near a 1000‐kV ultra‐high‐voltage AC transmission line, then the performances of transient electric shocks when human bodies contacting a metal clothes hanger were investigated. The transient shock current characteristics and correlation between transient shock energy and human ...
Wangling He +7 more
wiley +1 more source
Pleiotropic phenotypic effects of the TaCYP78A family on multiple yield‐related traits in wheat
Summary Increasing crop yield depends on selecting and utilizing pleiotropic genes/alleles to improve multiple yield‐related traits (YRTs) during crop breeding. However, synergistic improvement of YRTs is challenging due to the trade‐offs between YRTs in breeding practices.
Meng Ma +13 more
wiley +1 more source
为了高效设计变电站接地网,提出一种应用CDEGS进行接地网设计的方法。通过实地测量待建变电站处的土壤电阻率参数,建立变电站实际运行的系统模型,充分考虑到变电站实际运行中最严重的线路运行单相接地短路故障电流入地情况,并将变电站出线架空地线的分流纳入考虑范围,以站内接触电压、跨步电压、地电位升等参数作为安全性指标对设计的接地网进行考核,设计得到两种可行的接地网设计方案,试验表明应用CDEGS进行接地网设计具有较强的可操作性,对各类设计人员而言,可以应用文中的接地网设计方法或者流程,对接地网进行设计 ...
李伟 +7 more
doaj
Evaluation of steady-state ground resistance by field measurement and CDEGS computation
In addition to the soil resistivity and size of the grounding system, grounding system configuration can influence the steady-state resistance (RDC) of a grounding system. The RDC of four to six configurations in three distinct soil conditions (sites 1 to 3) is measured using the fall-of-potential method and computed using the current distribution ...
Usman Muhammad +4 more
openaire +2 more sources
A simplified model of the 750kV tower is established by CDEGS software which is based on the Method Of Moment. The power frequency electric field distribution on the ground is achieved by software calculation and field-measuring.
Xu Bao-Qing +4 more
doaj +1 more source