Results 51 to 60 of about 6,570 (187)
The development of a position-sensitive CZT detector with orthogonal co-planar anode strips [PDF]
We report on the simulation, construction, and performance of prototype CdZnTe imaging detectors with orthogonal coplanar anode strips. These detectors employ a novel electrode geometry with non-collecting anode strips in one dimension and collecting ...
Hamel, L A +7 more
core +2 more sources
Modeling and Verification of 1/f Noise Mechanisms in FAPbBr3 Single‐Crystal X‐Ray Detectors
We demonstratethat surface‐trap‐induced carrier number fluctuations are the dominantmechanism in FAPbBr3 Schottky devices, a conclusion supported by thedistinct defect profiles revealed by Drive‐Level Capacitance Profiling (DLCP). Throughnoise contribution decomposition, it is found that the 1/f noise of thedetector is the key noise source affecting ...
Zhongyu Yang +6 more
wiley +1 more source
The estimation of the characteristic parameters of the electrical contacts in CdZnTe and CdTe detectors is related to the identification of the main transport mechanisms dominating the currents.
Fabio Principato +3 more
doaj +1 more source
CdZnTe strip detectors as sub-millimeter resolution imaging gamma radiation spectrometers [PDF]
We report γ-ray detection performance measurements and computer simulations of a sub-millimeter pitch CdZnTe strip detector. The detector is a prototype for γ-ray measurements in the range of 20-600 keV.
Boykin, V +12 more
core +2 more sources
Pulse-shape discrimination of surface events in CdZnTe detectors for the COBRA experiment
Events near the cathode and anode surfaces of a coplanar grid CdZnTe detector are identifiable by means of the interaction depth information encoded in the signal amplitudes.
Durst, Jürgen +19 more
core +1 more source
Three-dimensional imaging and detection efficiency performance of orthogonal coplanar CZT strip detectors [PDF]
We report on recent three-dimensional imaging performance and detection efficiency measurements obtained with 5 mm thick prototype CdZnTe detectors fabricated with orthogonal coplanar anode strips.
Bernard, G +9 more
core +3 more sources
Halide Perovskite Radiation Detectors: Conventional Imaging Applications and New Opportunities
Organic–inorganic hybrid halide perovskite (OIHP) semiconductors, owing to their exceptional optoelectronic properties, are emerging as promising next‐generation integrated radiation detectors for applications in medical radiodiagnosis and healthcare monitoring.
Dou Zhao +4 more
wiley +1 more source
Progress in the study of CdZnTe strip detectors [PDF]
We report new performance measurements and computer simulations of a sub-millimeter pitch CdZnTe strip detector under study as a prototype imaging spectrometer for astronomical x-ray and gamma-ray observations.
Courville, J F +8 more
core +2 more sources
Point defect characterization in CdZnTe [PDF]
Measurements of the defect levels and performance testing of CdZnTe detectors were performed by means of Current Deep Level Transient Spectroscopy (I-DLTS), Transient Charge Technique (TCT), Current versus Voltage measurements (I–V), and gamma-ray spectroscopy.
Gul, R. +5 more
openaire +1 more source
Millimeter‐thickness polycrystalline metal halide perovskites (MPMHPs) demonstrate outstanding performance in X‐ray detection and hold promise for applications in high‐resolution imaging at low doses. This review provides a summary of research on X‐ray detectors utilizing MPMHP, encompassing various technologies and optimization strategies. Ultimately,
Yanshuang Ba +11 more
wiley +1 more source

