Results 101 to 110 of about 49,708 (287)

Area-efficient readout with 14-bit SAR-ADC for CMOS image sensors

open access: yesMATEC Web of Conferences, 2016
This paper proposes a readout design for CMOS image sensors. It has been squeezed into a 7.5um pitch under a 0.28um 1P3M technology. The ADC performs one 14-bit conversion in only 1.5us and targets a theoretical DNL feature about +1.3/-1 at 14-bit ...
Aziza Sassi Ben, Dzahini Daniel
doaj   +1 more source

Pixel Detectors

open access: yes, 2005
Pixel detectors for precise particle tracking in high energy physics have been developed to a level of maturity during the past decade. Three of the LHC detectors will use vertex detectors close to the interaction point based on the hybrid pixel ...
Wermes, Norbert
core   +1 more source

Similarities Between Proton and Neutron Induced Dark Current Distribution in CMOS Image Sensors [PDF]

open access: yes, 2012
Several CMOS image sensors were exposed to neutron or proton beams (displacement damage dose range from 4 TeV/g to 1825 TeV/g) and their radiation-induced dark current distributions are compared.
Bardoux, Alain   +7 more
core   +3 more sources

Chamber‐Specific Decellularized Extracellular Matrices Differentially Modulate Cardiomyocyte Subtypes to Drive Engineered Heart Tissue Development and Function

open access: yesAdvanced Healthcare Materials, EarlyView.
Chamber‐specific decellularized extracellular matrices (ECMs) were developed, preserving native proteomic profiles of ventricular and atrial myocardium. These innate biochemical cues differentially modulate cardiomyocyte subtypes to drive engineered heart tissue development and function, highlighting the importance of incorporating regional ECM cues in
Dong Gyu Hwang   +7 more
wiley   +1 more source

CMOS detectors for space applications: from R&D to operational program with large volume foundry [PDF]

open access: yes, 2010
Nowadays, CMOS image sensors are widely considered for space applications. The use of CIS (CMOS Image sensor) processes has significantly enhanced their performances such as dark current, quantum efficiency and conversion gain.
Breart de Boisanger, Michel   +6 more
core   +1 more source

Smart CMOS image sensor for lightning detection and imaging

open access: yesApplied Optics, 2013
We present a CMOS image sensor dedicated to lightning detection and imaging. The detector has been designed to evaluate the potentiality of an on-chip lightning detection solution based on a smart sensor. This evaluation is performed in the frame of the predevelopment phase of the lightning detector that will be implemented in the Meteosat Third ...
Rolando, Sébastien   +12 more
openaire   +4 more sources

Paracrine Factor Local Gradient‐Generating System for Engineering Perfusable Vascularized Hepatocyte Tissues with Perfusion‐Induced Proliferation

open access: yesAdvanced Healthcare Materials, EarlyView.
A paracrine factor local gradient (PFLG)‐generating system enables microvessel penetration across 3D hepatocyte tissues. The resulting vascularized constructs recapitulate hepatic sinusoidal hepatocyte—endothelial contact architecture and enhance hepatic functions in vitro.
Yen‐Hsiang Huang   +2 more
wiley   +1 more source

Image lag optimisation in a 4T CMOS image sensor for the JANUS camera on ESA's JUICE mission to Jupiter [PDF]

open access: yes, 2018
The CIS115, the imager selected for the JANUS camera on ESA’s JUICE mission to Jupiter, is a Four Transistor (4T) CMOS Image Sensor (CIS) fabricated in a 0.18 µm process.
Allanwood, E. A. H.   +6 more
core   +1 more source

Optoelectrical Devices for Neural Interfacing: Engineering Integration, Stability, and Multimodal Sensing

open access: yesAdvanced Healthcare Materials, EarlyView.
Implantable optoelectrical devices are an effective resource for the modulation and monitoring of neural activity with high spatiotemporal resolution. This review discusses current challenges faced by these devices and outlines future perspectives for the development of next‐generation neural interfaces targeting chronic, multisite, and multimodal ...
Stella Aslanoglou   +4 more
wiley   +1 more source

Extracellular Vesicles Modulation by an Adiponectin Receptor Agonist Provides Cardioprotection for Myocardial Ischemic Injury

open access: yesAdvanced Healthcare Materials, EarlyView.
This study demonstrates that ALY688, a drug mimicking the heart‐protective hormone adiponectin, reduces myocardial ischemia injury. ALY688 increases the production of extracellular vesicles, which carry protective cargo including adiponectin itself.
Jialing Tang   +13 more
wiley   +1 more source

Home - About - Disclaimer - Privacy