Results 181 to 190 of about 1,125,582 (236)

Volatile ZrO2 Antiferroelectric Tunnel Junctions for Rapid, Energy‐Efficient Physical Reservoir Computing

open access: yesAdvanced Science, EarlyView.
An antiferroelectric tunnel junction serves as a reservoir computing node, where field‐induced phase transitions and spontaneous ZrO2 relaxation deliver nonlinear fading memory. An In‐Ga‐Zn oxide interlayer enlarges the memory margin and multibit state richness.
Taegyu Kwon   +13 more
wiley   +1 more source

Probing Electrocatalyst Design for Product Selectivity in CO2 Reduction

open access: yesAdvanced Science, EarlyView.
Selective CO2 electroreduction is controlled by catalyst structure, dynamic surface reconstruction, adsorbate interactions, and reaction microenvironment. This review summarizes Cu‐ and non‐Cu‐based catalysts, single‐atom and molecular systems, degradation pathways, and operando/computational strategies for steering CO2RR toward hydrocarbons ...
Suvodeep Sen   +5 more
wiley   +1 more source

Ferroelectric Catalysts in the Hydrogen Evolution Reaction: A Perspective

open access: yesAdvanced Science, EarlyView.
This perspective summarizes recent advances in ferroelectric (FE) catalysts for the hydrogen evolution reaction (HER). It first introduces HER fundamentals and FE mechanisms, then classifies FE catalysts into single‐phase, single‐atom‐modified, heterostructured, and other engineered types, with representative examples.
Rongxuan Lu   +6 more
wiley   +1 more source

Review of Gastrointestinal Capsule Robots: Materials, Actuation, Diagnostics, and Therapeutics

open access: yesAdvanced Science, EarlyView.
This review examines gastrointestinal capsule robots through a systems engineering lens, covering shell materials, actuation and localization strategies, diagnostic modalities, therapeutic interventions, and commercialization status. By mapping the complete technological chain from fabrication to clinical deployment, this work identifies critical gaps ...
Zengsheng Li   +8 more
wiley   +1 more source

Voltage‐Reconfigurable Magneto‐Ionic Nanolayers in Dot Arrays for Probabilistic, Materials‐Engineered Security Primitives

open access: yesAdvanced Science, EarlyView.
A magneto‐ionic security‐by‐materials‐design strategy exploits voltage‐driven N3– migration in selectively contacted FeCoN dots, creating reconfigurable sub‐15 nm ferromagnetic sublayers with deterministic and/or probabilistic (single‐domain↔vortex) states, voltage‐tunable probabilities and fully stochastic orientation/chirality.
Irena Spasojevic   +4 more
wiley   +1 more source

Multispectral UV Imaging on Capacitive CMOS Arrays Enabled by Solution‐Processed Metal‐Oxide Nanoparticles

open access: yesAdvanced Science, EarlyView.
Ultraviolet (UV) imagers are important for a variety of applications but often require dedicated semiconductor process flows. Here, a versatile capacitive CMOS platform is transformed into a visible‐blind, multispectral UV imager through post‐CMOS functionalization with solution‐processed metal‐oxide nanoparticles. The UV‐induced photodielectric effect
Suman Kundu   +5 more
wiley   +1 more source

Differential Tissue‐Coupled Powering for Battery‐Free Injectable Electroceuticals

open access: yesAdvanced Science, EarlyView.
A thread‐like injectable neural stimulator is powered through differential tissue‐coupled powering (DTCP), which harvests RF‐frequency tissue potentials with an elongated receiver while preserving a injectable cross‐section. The system integrates an ASIC, stimulation electrodes, and a portable transmitter, enabling wireless peripheral nerve stimulation,
Han Wu   +13 more
wiley   +1 more source

EndoTac: An Endoscopic Camera‐Based Tactile Sensor with High Sensitivity for Minimally Invasive Surgery

open access: yesAdvanced Science, EarlyView.
EndoTac presents a trocar‐compatible endoscopic vision‐based tactile sensor that uses a convex mirror to enlarge side‐facing tactile coverage during minimally invasive vessel palpation. Distorted tactile images are unwarped and processed by a learning model to estimate vascular deformation, enabling sensitive, spatially distributed tactile perception ...
Yupeng Wang   +5 more
wiley   +1 more source

Drop‐Location‐Insensitive Droplet‐Based Electricity Generator Using Polydimethylsiloxane Slippery Covalently Attached Liquid Coatings

open access: yesAdvanced Science, EarlyView.
Drop‐location sensitivity remains a key barrier to practical droplet‐based electricity generators (DEGs). Here, a polydimethylsiloxane slippery covalently attached liquid (PDMS‐SCAL)‐coated interface promotes droplet sliding instead of splitting or bouncing, allowing stable electricity generation from randomly falling raindrops. The resulting PDMS‐SCAL‐
Jung Bin Yang   +6 more
wiley   +1 more source

Single‐Sensor Vibration Sensing in Anisotropic Composites Enabled by Disordered Metasurfaces

open access: yesAdvanced Science, EarlyView.
This work develops a single‐sensor vibration sensing (SSVS) framework that integrates disordered metasurfaces with compressive sensing. Comprehensive numerical and experimental validations demonstrate that, by manipulating anisotropic guided wave propagation through metasurfaces, the proposed SSVS framework enables high‐fidelity multi‐source vibration ...
Jianjie Zhang   +6 more
wiley   +1 more source

Home - About - Disclaimer - Privacy