Results 51 to 60 of about 10,694 (182)
The effects of the real-time changes in the microenvironment within the crevice caused by the change in crevice size on the induction of crevice corrosion of 201 stainless steel (201-SS) in 1 M (pH = 4.00) NaCl solution were evaluated using conventional ...
Hao-Jing Ge +7 more
doaj +1 more source
Stainless steel fasteners can fail as a result of stress corrosion cracking (SCC) in coastal atmosphere. In order to have a better understanding of the development of stainless steel fasteners’ SCC in marine atmospheric, the corrosion electrochemistry ...
Huang Yanliang, Yu Xiuming, Qu Wenjuan
doaj +1 more source
The Influence of Inhibitor Ions on Dissolution Kinetics of Al and Mg Using the Artificial Crevice Technique [PDF]
This work was supported by the Strategic Environmental Research and Development Program under contract no. DACA72-99- C-0002, and the Air Force Office of Scientific Research under contract no.
Frankel, Gerald S. +2 more
core +2 more sources
Bipolar electrochemistry allows testing and analysing the crevice corrosion, pitting corrosion, passivation, general corrosion, and cathodic deposition reactions on one sample after a single experiment.
Yiqi Zhou, Dirk Lars Engelberg
doaj +1 more source
Analysis of corrosion damage in a boiler made of AISI 304L stainless steel
The corrosion damage near the welded joint in the boiler of AISI 304L stainless steel was analysed. During welding, heat tint was formed near the weld on the inner surface of the boiler, because shielded gas was not applied.
Biljana Bobić +2 more
doaj +1 more source
An electrode array probe has been specially designed and demonstrated for in situ monitoring and visualising multiple localised corrosion processes and mechanisms, including crevice, weldment and pitting corrosion, occurring simultaneously on marine ...
Majid Laleh +3 more
doaj +1 more source
The SCC of N80 carbon steel with varying crevice opening dimensions is investigated by electrochemical measurements, mechanical tests, surface analysis and hydrogen detection. The presence of a crevice structure can induce significant galvanic corrosion,
Xiaoshun Zhang +3 more
doaj +1 more source
Failure of Emperion modular femoral stem with implant analysis
Modularity in total hip arthroplasty provides multiple benefits to the surgeon in restoring the appropriate alignment and position to a previously damaged hip joint.
Benjamin M. Stronach, MD, MS +2 more
doaj +1 more source
Screen-printed platinum electrodes were used to monitor crevice corrosion processes. The electrodes, printed on an inert alumina substrate, formed the bottom of an artificial crevice when mechanically clamped to a rectangular block of nickel-aluminium ...
Cranny, Andrew +6 more
core
A Corrosion Control Manual for Rail Rapid Transit [PDF]
This manual addresses corrosion problems in the design, contruction, and maintenance of rapid transit systems. Design and maintenance solutions are provided for each problem covered.
Fitzgerald, J. H., III +3 more
core +4 more sources

