Results 31 to 40 of about 2,763 (226)
The physical and thermal properties of modified rotational molding grade silane cross-linked polyethylene compound [PDF]
This study is aimed at investigating the physical and thermal properties of the modified rotational molding grade cross-linked polyethylene compound with respect to process ability. Rotational molding grade High Density Polyethylene (HDPE) was blended at
Ahmad, Fareed +2 more
core +1 more source
IMPROVEMENT OF DIELECTRIC STRENGTHS FOR CROSS-LINKED POLYETHYLENE (XLPE) MEDIUM VOLTAGE CABLES
The electricity distribution companies are interested of the types of polymeric materials used in medium voltage cables which is considered the basis of power grid. In this study, it tried to enhance the electrical properties of cross-linked polyethylene (XLPE) after adding inorganic filler: such as Silica (SiO2) filler with 10%, 20%, 30% and 40 ...
Loai Nasrat, Mostafa Ali, Karar Mahmoud
openaire +2 more sources
Influence of thermal treatment and residues on space charge accumulation in XLPE for DC power cable application [PDF]
Effects of cross-linking by-products (residues) of polyethylene on space charge accumulation and decay are investigated in the paper using the pulsed electro-acoustic technique.
Chen, G. +3 more
core +1 more source
The demand for internal nondestructive testing and inspection techniques is rapidly increasing. Using a continuous wave (CW) terahertz (THz) imaging system, we demonstrate that the internal defects in cross-linked polyethylene (XLPE) plates for power ...
In-Sung Lee, Joong Wook Lee
doaj +1 more source
To study the effect of antioxidant and graphite nanoplatelets ( GNPs) on the direct current ( DC) dielectric properties of cross-linked polyethylene ( XLPE ) ,antioxidant /XLPE and GNPs/antioxidant /XLPE composites were prepared by melt blending method ...
ZHANG Cheng-cheng +4 more
doaj +1 more source
Electric field requirements for charge packet generation and movement in XLPE [PDF]
The formation of space charge packets in XLPE (Cross-linked polyethylene) tapes from unaged cable insulation has been studied utilising the pulsed electro-acoustic (PEA) technique.
Dissado, L. A. +2 more
core +1 more source
DC cross-linked polyethylene (XLPE) power cables are being used recently for HV/EHV applications, the reliability of which is claimed to be significantly affected by space charge accumulation in the insulating material.
Zhipeng Lei +8 more
doaj +1 more source
The effect of degassing on morphology and space charge
It is believed that space charge buildup in cross-linked polyethylene (XLPE) insulation is the main cause for premature failure of underground power cables. The space charge activities in XLPE depend on many factors such as additives, material treatment,
Chen, G, Chong, Y L, Ho, Y F F
core +1 more source
Correlation Between Thermal Parameters and Morphology of Cross-Linked Polyethylene
This paper reveals a correlation between morphology and thermal parameters on cross-linked polyethylene (XLPE) cable with different insulating states. Several cables were selected to detect the physicochemical and thermal parameters of the XLPE.
Yifeng Zhao +9 more
doaj +1 more source
Abstract This paper describes changes on micro-structure and aggregation structure of cross-linked polyethylene (XLPE) with different thermal histories after different times of overheating treatment to analogize the short-term fault or emergency overload in actual operating cables.
Wenwei Zhu +5 more
openaire +1 more source

