Results 41 to 50 of about 2,763 (226)

Research and Development of 66 kV Water Tree Retardant XLPE Light Insulated Submarine Cable

open access: yesZhongguo dianli, 2020
This paper introduces the development method of a light submarine cable with rated voltage of 66 kV and water tree retardant cross linked polyethylene insulation(XLPE).
Guo CHEN   +6 more
doaj   +1 more source

Evaluation of Moisture Ageing Status of Cross‐Linked Polyethylene Insulation in Power Cables at Different Temperatures

open access: yesHigh Voltage, EarlyView.
ABSTRACT Cross‐linked polyethylene (XLPE) cables play an important role in power systems to transport electrical energy, and moisture is one of the important predisposing factors for insulation failure in medium and high‐voltage cables. In this paper, a temperature‐moisture accelerated ageing experiment is designed, and a method for assessing the ...
Wen Luo   +7 more
wiley   +1 more source

Significantly enhanced DC breakdown strength and high‐temperature resistivity of cross‐linked polyethylene through alloying polystyrene strategy

open access: yesHigh Voltage
Developing a stable insulation material stands as a crucial challenge for high‐voltage direct current (HVDC) cable insulation. This work proposes an alloying strategy to significantly enhance the breakdown strength and high‐temperature resistivity of ...
Muneeb Ahmed   +6 more
doaj   +1 more source

Pineapples internal quality inspection approaches and its potential effects in Malaysia [PDF]

open access: yes, 2020
Pineapple (Ananas Comosus L. Metil) is a tropical plant under Bromeliaceous family that is grown in American tropics, subtropics, and warmer regions (U. Nations 2012). Pineapple is the second harvest tropical fruit after banana in the world (S.
Jam, Mohamad Nur Hakim   +2 more
core  

Time‐Domain Computation of Propagation Characteristics of Partial Discharge in Cross‐Linked Polyethylene High‐Voltage Cable Incorporating Modified Frequency‐Dependent Parameters

open access: yesHigh Voltage, EarlyView.
ABSTRACT The propagation characteristics of partial discharge (PD) in cables impact PD detection sensitivity, defect localisation accuracy and defect severity evaluation. Currently, the effects of semiconducting materials' frequency‐dependent properties and corrugated aluminium sheath structures on PD signal propagation in high‐voltage (HV) cables ...
Weisheng He   +6 more
wiley   +1 more source

Experimental investigation of E-beam effect on the electric field distribution in cross-linked polyethylene/ZnO nanocomposites for medium-voltage cables simulated by COMSOL Multiphysics

open access: yesJournal of Analytical Science and Technology, 2022
This study investigated the electric field distribution of underground cable insulation in cross-linked polyethylene/zinc oxide (XLPE/ ZnO) nanoparticles (NPs) for medium-voltage (MV) cables. The ZnO NPs that were obtained by three methods of preparation
A. I. Sharshir   +5 more
doaj   +1 more source

Space Charge Accumulation under Effects of Temperature Gradient and Applied Voltage Reversal on Solid Dielectric DC Cable [PDF]

open access: yes, 2009
A well-known fact of the existence and accumulation of space charge within the insulating material poses threat to the reliability in the operation of dc power cables.
Chen, George   +2 more
core   +1 more source

Effects of Exposure to Radiation and Steam on Silicone Rubber Cables Removed From a Nuclear Power Plant

open access: yesHigh Voltage, EarlyView.
ABSTRACT Low‐voltage cables insulated with silicone rubber were harvested from three locations in the primary containment vessel of a boiling water nuclear power plant (NPP). Subsequently, the cable, which was placed in an ambient environment with a relatively higher temperature and the highest rate, was cut into four shorter ones.
Yoshimichi Ohki   +2 more
wiley   +1 more source

Research on the discharge characteristics of XLPE insulated DC cables

open access: yesAIP Advances, 2021
This paper focuses on the discharge of cross-linked polyethylene (XLPE) insulated DC cables, which has become a concern of power utilities when carrying out a voltage withstand test or an outage maintenance.
Ying Liu, Xinlong Zheng
doaj   +1 more source

Temperature effect on space charge dynamics in XLPE insulation [PDF]

open access: yes, 2007
This paper reports on space charge evolution in crosslinked polyethylene (XLPE) planar samples approximately 1.20 mm thick subjected to electric stress level of 30 kVdc/mm under four temperature 25 oC, 50 oC, 70 oC and 90 oC for 24 hours.
Chen, G, Chong, Y L, Ho, Y F F