Stochastic seismic response of building with shape memory alloy damper [PDF]
The present study focuses on the estimation of response of building structure supplemented with the superelastic shape memory alloy (SMA) damper under the stochastic seismic excitation.
Kashyap Shubham +2 more
doaj +1 more source
Influence of Internal Rubber Damper on Cable External Viscous Damper Effectiveness
In practice, the internal rubber dampers are widely installed inside the cable guide pipe between the external viscous damper and the cable anchorage. In order to study the effect of the internal damper on the performance of the external viscous damper ...
Changzhao Li +5 more
doaj +1 more source
In this paper, we report the effect of the installation angle of a separated dual chamber single rod type damper using elastomer particles on the damping force characteristics.
Atsushi TOYOUCHI +3 more
doaj +1 more source
Damping force switching type electromagnetic damper using relay and capacitor
In general, semiactive dampers have high performance of vibration control compared to passive dampers, but in order to adjust an optimized damping force for the damper, several condition of vibration systems, such kind of force, acceleration and ...
Taichi MATSUOKA, Taichi NAKAZAWA
doaj +1 more source
An innovative passive energy damper is introduced and studied experimentally and numerically. This damper is designed as the main plate for energy absorption which is surrounded by an octagon cover.
Ali Ghamari +4 more
doaj +1 more source
We investigated the damping mechanism of granular material dampers when using a structure with a relatively high natural frequency and small vibration displacement as the target of vibration damping.
Tomoko KOGA, Taichi SATO
doaj +1 more source
Supression of mechanical oscillations in a nonlinear systems with restriction
The application of the dynamical dampers in the mechanical systems, when the sources of stimulation are impossible to abolish, is one of the ways to fight against the harmful vibrations.
Genovaitė Zaksienė
doaj +3 more sources
In the maintenance of cable structures, such as cable-stayed bridges, cable safety is assessed based on the cable tension. In Japan, the cable tension is generally estimated from the cable’s natural frequencies using the higher-order vibration method. In
Aiko Furukawa +2 more
doaj +1 more source
Seismic Performance Evaluation of Building-Damper System under Near-Fault Earthquake
The building-damper system designed by a seismic code is usually considered to be able to withstand the attack of strong earthquakes. However, near-fault earthquakes, especially those with the forward-directivity effect, might cause early and unexpected ...
Xiaoli Wu +5 more
doaj +1 more source
A Concentric Design of a Bypass Magnetorheological Fluid Damper with a Serpentine Flux Valve
This work presents a new concentric design structure of a bypass magnetorheological (MR) damper with a serpentine flux valve type. In this design, the serpentine valve is installed not in the middle of the piston but on the bypass channel of the damper ...
Muhammad Hafiz Idris +4 more
doaj +1 more source