Results 61 to 70 of about 6,327 (313)

Electrical Conductivities of Conductors, Semiconductors, and Their Mixtures at Elevated Temperatures

open access: yesAdvanced Engineering Materials, EarlyView.
This article presents a comprehensive review of temperature‐dependent electrical conductivity data for multiple material classes at elevated temperatures, highlighting a persistent conductivity gap between metals and semiconductors in the range of 102$\left(10\right)^{2}$– 107$\left(10\right)^{7}$ S/m. Metal–ceramic irregular metamaterials are proposed
Valentina Torres Nieto, Marcia A. Cooper
wiley   +1 more source

Characterization of a Recyclate‐Based MgO‐Steel Composite As‐Sintered Inert Anode Candidate After Exposure to Cryolite Electrolysis

open access: yesAdvanced Engineering Materials, EarlyView.
Carbon‐free inert anodes are essential for decarbonizing aluminum electrolysis. This study investigates a recyclate‐based MgO‐316L steel composite anode tested under galvanostatic Hall–Héroult conditions in cryolite at 1000°C. Microstructural analysis reveals selective MgO fluorination, spinel and oxide layer formation, electrolyte infiltration, and ...
Serhii Yaroshevskyi   +7 more
wiley   +1 more source

A New Hard Switching Bidirectional Converter With High Power Density [PDF]

open access: yesJournal of Intelligent Procedures in Electrical Technology, 2010
In this paper, a new isolated dc-dc bidirectional converter is proposed. This converter consists of two transformers (flyback and forward) and only one switch in primary side and one switch in secondary side of transformers.
Bahador Fani   +2 more
doaj  

Resistance Rapid Heating of Aluminum Coatings in an Extreme High Vacuum–Adequate Atmosphere for Hot Stamping

open access: yesAdvanced Engineering Materials, EarlyView.
The subject of this work is the development of a corrosion‐protective coating on steel sheets for form hardening. Rapid heating in an extreme high vacuum (XHV)‐adequate atmosphere is a useful method to prevent oxidation during alloying of 22MnB5 and aluminum to obtain a metallurgical bonding.
Lorenz Albracht   +5 more
wiley   +1 more source

Development of an Electromagnetic‐Thermal Circuit Model for Single‐Phase Three‐Limb Transformers

open access: yesHigh Voltage
Analysing the heat states of transformers under DC bias requires careful consideration of their own structural and material characteristics. Although the 3D finite element method (FEM) is a reliable way of simulating all the details of transformers, it ...
Yidan Hu   +5 more
doaj   +1 more source

Design Algorithm for and Validation of Winding Losses in Large-Capacity Medium-Frequency Distribution Transformers

open access: yesEnergies
Accurately calculating winding losses has always been a significant challenge in the design of large-capacity medium-frequency transformers. This paper presents an accurate design algorithm for calculating the winding losses of a large-capacity medium ...
Tao Jiang, Zhe Yang
doaj   +1 more source

Surface Tension Measurement of Ti‐6Al‐4V by Falling Droplet Method in Oxygen‐Free Atmosphere

open access: yesAdvanced Engineering Materials, EarlyView.
In this article, the temperature‐dependent surface tension of free falling, oscillating Ti‐6Al‐4V droplets is investigated in both argon and monosilane doped, oxygen‐free atmosphere. Droplet temperature and oscillation are captured with one single high‐speed camera, and the surface tension is calculated with Rayleigh's formula.
Johannes May   +9 more
wiley   +1 more source

Topology and Control of Current-Fed Quadruple Active Bridge DC–DC Converters for Smart Transformers with Integrated Battery Energy Storage Systems

open access: yesEnergies
Smart transformers (STs), which are power electronic-based transformers with control and communication capabilities, facilitate managing future distribution grids with distributed generators (DGs) and battery energy storage systems (BESSs).
Kangan Wang   +4 more
doaj   +1 more source

Design and Optimization of Three-Phase Dual-Active-Bridge Converters for Electric Vehicle Charging Stations

open access: yesEnergies, 2019
In this paper, design and optimization method of a three-phase dual-active-bridge DC/DC converter is discussed. Three single phase transformers connected in star-star configuration were designed with large leakage inductance aiming to eliminate the need ...
Duy-Dinh Nguyen   +2 more
doaj   +1 more source

In Situ Constructed Magnetic Core‐Shell Hydrogen‐Bonded Organic Framework‐on‐Metal–Organic Framework Structure: an Efficient Catalyst for Peroxymonosulfate Activation

open access: yesAdvanced Functional Materials, EarlyView.
In this work, a magnetic core‐shell catalyst (HOF‐on‐Fe3O4/ZIF‐67) is successfully synthesized, consisting of a metal–organic framework (ZIF‐67) with magnetic Fe3O4 as the core and a porous hydrogen‐bonded organic framework (HOF) as the shell. The catalyst efficiently activated peroxymonosulfate, resulting in rapid and effective removal of water ...
Yingying Du   +4 more
wiley   +1 more source

Home - About - Disclaimer - Privacy