Results 31 to 40 of about 2,051,359 (297)
Indirect determination of lutetium by differential pulse anodic stripping voltammetry at a hanging mercury drop electrode [PDF]
Lutetium has been determined by differential pulse anodic stripping voltammetry in an acidic solution containing Zn-EDTA. Lutetium (III) ions liberated zinc (II), which was preconcentrated on a hanging mercury drop electrode and stripped anodically ...
Ignjatović, Ljubiša M. +7 more
core +1 more source
The electrochemical analysis of theophylline (THP) was investigated by fabricating a carbon paste electrode (CPE) modified with graphene oxide (GO) along with copper oxide (CuO) nanoparticles (CuO-GO/CPE). The impact of electro-kinetic parameters such as
Vinoda B. Patil +5 more
doaj +1 more source
Determination of epinephrine in the presence of uric acid and folic acid using nanostructure-based electrochemical sensor [PDF]
Fabrication and electrochemical characterization of a sensor for the determination of epinephrine (EP), uric acid (UA) and folic acid (FA) is described. The sensor was prepared using carbon paste electrode (CPE) modified with 3,4-dihydroxybenzaldehyde-2,
M. Mazloum-Ardakani +3 more
doaj +1 more source
The Differential Alternative Pulses Voltammetry (DAPV) combining the high sensitivity of the Differential Pulse Voltammetry with the increased resolution of the second order voltammetric techniques was applied for on-site simultaneous determination of ...
Benjamin Valdez +4 more
core +1 more source
Donor‐Engineered Chiral Indium–Salen Complexes for Tunable Circularly Polarized Luminescence
Chiral indium–salen complexes bearing electronically and structurally diverse donor substituents are presented as modular main‐group luminophores exhibiting tunable blue‐to‐green circularly polarized luminescence. Donor engineering systematically controls frontier‐orbital distribution, intraligand charge transfer, and excited‐state relaxation ...
Haein Kim +14 more
wiley +1 more source
DIFFERENTIAL PULSE ANODIC STRIPPING VOLTAMMETRY FOR DETERMINATION OF SOME HEAVY METALS IN URANIUM [PDF]
The direct determination of some metals impurity in uranium by using differential pulse anodic stripping voltammetry (DPASV) method at a hanging mercury drop electrode and in a carbonate buffer media was developed.
Saryati Saryati
core +1 more source
Nitride MXenes remain constrained by a persistent gap between computational prediction and experimental realization. This Review identifies the thermodynamic, kinetic, and chemical barriers limiting their synthesis, critically evaluates emerging fabrication routes, and proposes a multidimensional computational‐experimental framework to accelerate the ...
Naresh Varnakavi, Masoud Soroush
wiley +1 more source
A spatial location of atomic layer deposition (ALD)‐derived ZrO2 coatings is demonstrated to be a critical design parameter for stabilizing graphite cathodes in DIBs. Direct particle‐level ALD (PALD) screening of representative metal oxides identified ZrO2 as the coating that provides the most favorable balance of high‐rate capability and interfacial ...
Jieun Kang +7 more
wiley +1 more source
A cost-effective and environment-friendly electrochemical sensor based on waste-battery graphite electrodes is developed. The electrodes were extracted from different brands of waste zinc‑carbon batteries and were used as the working electrode in ...
Shirley T. Palisoc +6 more
doaj +1 more source
Magneto‐Ionic Devices With Polymer‐Based Electrolytes
Polymer electrolytes are introduced for magneto‐ionic devices based on hydroxide and hydrogen ions. The magneto‐ionic effect results in a pronounced voltage‐controlled variation of coercivity in both devices. The switching speed is in the range of 100 ms.
Markus Gößler +3 more
wiley +1 more source