Results 131 to 140 of about 156,789 (313)

Clinical Research with Advanced Diffusion Encoding Methods in MRI

open access: yes, 2020
This chapter offers a comprehensive summary of applications of advanced diffusion encoding methods in MRI within a narrowly defined area of in vivo human measurements with imaging read-out and voxel-by-voxel data analysis.
Y. Zheng   +51 more
core   +1 more source

Natural Biomaterials for Osteochondral Repair: From Source to Strategy

open access: yesAdvanced Healthcare Materials, EarlyView.
Biological origin‐guided overview of natural biomaterials and therapeutic strategies for osteochondral tissue engineering. The circular diagram categorizes representative materials and strategies into plant/algae‐derived, microbial‐derived, animal‐derived, and human‐derived sources, centered on an osteochondral defect repair model.
Hengyu Liu   +5 more
wiley   +1 more source

Water Permeates and Plasticizes Amorphous Carbon Dots: Unraveling the Inner Accessibility of the Nanoparticles by Glass Transition Studies

open access: yesAdvanced Materials, EarlyView.
The water permeability of amorphous carbon dots (CDs) is demonstrated by investigating their plasticization. Novel polyamide‐based and amorphous nanoparticles are synthesized by controlling their inner packing density. Water plasticization is evidenced by the decrease of the CDs glass transition temperature with increasing the hydration degree.
Elisa Sturabotti   +8 more
wiley   +1 more source

Super‐Resolution Ultrasound Based Cell Tracking With Polymeric Nanobubbles

open access: yesAdvanced Materials, EarlyView.
This study presents a super‐resolution ultrasound platform for tracking cells in vivo. Biocompatible polymeric nanobubbles are used as highly echogenic intracellular labels. Following the injection of cells and microbubbles, ultrasound localization microscopy (ULM) can dynamically match the microvascular architecture and individual cell trajectories ...
Junlin Chen   +19 more
wiley   +1 more source

Three-year follow-up of human transplanted kidneys by diffusion-weighted MRI and blood oxygenation level-dependent imaging

open access: yes, 2011
To prospectively determine the 3-year stability and potential changes of functional parameters in renal allograft recipients obtained from diffusion-weighted imaging (DWI) and blood oxygenation level-dependent (BOLD ...
Thoeny, Harriet C   +9 more
core   +1 more source

3D Printing of Soft Robotic Systems: Advances in Fabrication Strategies and Future Trends

open access: yesAdvanced Robotics Research, EarlyView.
Collectively, this review systematically examines 3D‐printed soft robotics, encompassing material selections, function integration, and manufacturing methodologies. Meanwhile, fabrication strategies are analyzed in order of increasing complexity, highlighting persistent challenges with proposed solutions.
Changjiang Liu   +5 more
wiley   +1 more source

High resolution MRI of the brain at 4.7 Tesla using fast spin echo imaging

open access: yes, 2003
Over recent years, high field MR scanners (3 T and above) have become increasingly widespread due to potential advantages such as higher signal-to-noise ratio.
Thomas, D.L.   +12 more
core   +1 more source

TacScope: A Miniaturized Vision‐Based Tactile Sensor for Surgical Applications

open access: yesAdvanced Robotics Research, EarlyView.
TacScope is a compact, vision‐based tactile sensor designed for robot‐assisted surgery. By leveraging a curved elastomer surface with pressure‐sensitive particle redistribution, it captures high‐resolution 3D tactile feedback. TacScope enables accurate tumor detection and shape classification beneath soft tissue phantoms, offering a scalable, low‐cost ...
Md Rakibul Islam Prince   +3 more
wiley   +1 more source

Magnetic Micro‐ and Nanorobots for Precision Thrombolysis: Design Strategies and Translational Challenges

open access: yesAdvanced Robotics Research, EarlyView.
Micro‐ and nanorobots for targeted thrombolysis. This perspective elaborates on the clinical indication of blood clot disorders and current limitations for treatment. As a novel, alternative solution, micro‐ and nanorobots can be used to treat and break down thrombi.
Joshua M. Mesfin   +3 more
wiley   +1 more source

Hardware considerations for diffusion MRI

open access: yes, 2011
This chapter discusses a diffusion experiment with ideal hardware. Nonideal behavior resulting from various causes, including pulsed field gradient induced eddy currents, radiofrequency inhomogeneity, and mechanical vibration, is considered.
Yadav, Nirbhay N. (S24980)   +2 more
core  

Home - About - Disclaimer - Privacy