Results 71 to 80 of about 216 (178)
A 23.7‐uW 93.5‐dB SNDR delta‐sigma modulator for healthcare and medical diagnostics
This paper presents a high‐precision, low‐power delta‐sigma modulator (DSM) designed for healthcare and medical diagnostics. It utilizes a hybrid switching integrator to reduce distortion caused by the non‐linear on‐resistance of switches at a low supply
Jianguo Hu +4 more
doaj +1 more source
The temperature dependence of fatigue behavior in nickel‐based superalloys is investigated through high‐resolution measurements of plastic localization. While increasing temperature reduces localization and enhances fatigue performance in René 88DT, Inconel 718 exhibits a sharp degradation at intermediate temperature due to intensified slip ...
M. Calvat +5 more
wiley +1 more source
Tailoring Functional Properties of Ti–Ni–Cu Shape Memory Alloy Thin Films for MEMS Actuators
A comprehensive study of critical parameters required to develop well‐performing Ti–Ni–Cu thin film shape memory alloy microactuators is provided. Materials science and device integration aspects are integrated by addressing structural and physical relationships using complementary characterization techniques as well as a practical fabrication solution
Elaheh Akbarnejad +6 more
wiley +1 more source
Influence of Test Temperature and Test Frequency on Fatigue Life of Aluminum Alloy EN AW‐2618A
The influence of test temperature and test frequency on the fatigue life of EN AW‐2618A is investigated. High‐cycle fatigue tests are performed at different test temperatures and frequencies on the 1000 h/230°C overaged state. Both test parameters reduce fatigue life due to time‐dependent damage mechanisms.
Ying Han +5 more
wiley +1 more source
Current Status and Challenges in Data Collection for Aerospace Coatings Deposited by Plasma Spraying
An innovative approach has been integrated into the GRENAT project to optimize plasma spraying and coating performance. Raw materials are accelerated and melted in the plasma generated by torches, creating coatings. Monitoring sensors collect process data which are combined with ex situ characterization data.
Lila Randriamananjara +8 more
wiley +1 more source
Soft Mechanical‐Electrical Logic Using Liquid Metal‐Filled 3D‐Printed Architectures
We present 3D‐printed soft mechanical–electrical logic elements that use liquid metal–filled silicone tubes actuated by thermoplastic polyurethane/polylactic acid (TPU/PLA) architectures to produce Boolean operations. Complementary normally open and normally closed unit cells perform repeatable binary transitions and can be combined into more complex ...
Christoph Lehmann +2 more
wiley +1 more source
Modern medical facilities place considerable reliance on electronic instrumentation for purposes of calibration and monitoring of therapeutic processes, many of which employ electrical and electronic apparatus that itself generates considerable levels of
Neil Robinson, Kerry Williams
doaj +1 more source
Enhanced Strength and Corrosion Resistance of Ti‐13Nb‐12Ta‐10Zr‐4Sn Alloy by Aging Treatment
This work systematically investigates the effect of aging treatment on mechanical properties and corrosion behavior of vacuum arc‐melted Ti‐13Nb‐12Ta‐10Zr‐4Sn alloy. Owing to the increased α″ martensite, strength and corrosion resistance were significantly enhanced by aging treatment.
Yuhua Li +5 more
wiley +1 more source
The article examines in a specialized language different variants of software provision in a specialized environment for conducting laboratory experiments on analogue and digital circuits.
Popov George, Krastev Filip
doaj +1 more source
Low‐voltage FIB‐SEM tomography combined with a image preprocessing pipeline improves phase contrast and enables reliable machine‐learning segmentation of conductive networks in lithium‐ion battery electrodes. Structural descriptors are extracted from segmented images, done semimanually and automated, and compared.
Lisa Beran +6 more
wiley +1 more source

