Results 51 to 60 of about 10,964 (180)
In the proposed method, carbon tetrachloride and ethanol were used as extraction and dispersive solvents. Several factors that may be affected on the extraction process, such as extraction solvent, disperser solvent, the volume of extraction and ...
Sayed Zia Mohammadi +4 more
doaj +1 more source
Photocatalytic degradation and mineralization of diazinon in aqueous solution using nano-TiO2(Degussa, P25): kinetic and statistical analysis [PDF]
: In this study, photocatalytic degradation of diazinon was investigated using nano-TiO2, Degussa P25, as a photocatalyst and the effects of some operational parameters such as aeration, pH, photocatalyst concentration, and the irradiation time were also
Asgharnia, H. +4 more
core
ABSTRACT Phytocannabinoids are bioactive metabolites derived from the Cannabis sativa plant. They have garnered attention due to their recreational uses and therapeutic potential. Although various analytical strategies have been employed for their analysis, mass spectrometry (MS) coupled to chromatographic separation is superior due to its sensitivity ...
Radwa Mahmoud +2 more
wiley +1 more source
Valproic acid extraction methods in human samples for gas chromatography analysis: a review
Valproic acid (VPA) is widely used as an important drug for the treatment of epilepsy, seizures, bipolar disorders, and migraines. However, its narrow therapeutic range lead to risks of unintentional poisoning and potential suicide.
Juliana Blume de Oliveira +2 more
doaj +1 more source
Dispersive liquid-liquid microextraction-gas chromatography-mass spectrometric determination of polycylic aromatic hydrocarbons in water [PDF]
In this work, a sample preparation method based on dispersive liquid-liquid microextraction (DLLME) coupled with gas chromatography-mass spectrometry (GC-MS) was developed for the extraction of polycyclic aromatic hydrocarbons (PAHs), namely phenanthrene
Sharef A., Sarra Younes
core
ABSTRACT The review examines the evolution of chemical ionization mass spectrometry (CI‐MS), a technique developed in 1966 by Field and Munson. CI is a soft‐ionization method that produces more intense molecular ions with less fragmentation than electron ionization (EI).
Malvika Dutt +4 more
wiley +1 more source
ABSTRACT Top‐down proteomics (TDP) characterizes proteoforms in cells, tissues, and biofluids, in discovery mode and on a global scale, requiring analytical tools with high peak capacity for proteoform separation and high sensitivity for proteoform detection, given the extremely high proteoform complexity and wide proteoform concentration dynamic range.
Guijie Zhu +5 more
wiley +1 more source
A simple ion pair-dispersive liquid-liquid microextraction method was proposed for preconcentration trace amounts of rhodium. An ion association complex of RhCl4- and tetradecyldimetylbenzylamonium was extracted into cholorobenzene.
Daryoush Afzali +2 more
doaj +1 more source
ABSTRACT The rhizosphere harbours critical plant‐herbivore interactions often mediated by small lipophilic molecules (SLMs). Despite the agricultural importance of many soil‐dwelling insects, surprisingly little is known about chemically mediated belowground crop‐pest interactions. Root and shoot herbivores can influence these interactions by modifying
Diego M. Magalhães +8 more
wiley +1 more source
Validation of an analytical method for determination of 13 priority polycyclic aromatic hydrocarbons in mineral water using dispersive liquid-liquid microextraction and GC-MS [PDF]
Dispersive liquid-liquid microextraction (DLLME) combined with gas chromatography–mass spectrometry (GC–MS) was used for the extraction and determination of 13 polycyclic aromatic hydrocarbons (PAHs) in mineral water samples.
Bayat, Mitra. +4 more
core

