Results 101 to 110 of about 3,922 (300)

A detection algorithm of voltage sag used in dynamic voltage restorer

open access: yesGong-kuang zidonghua, 2013
In view of contradiction between compensation rapidity and anti-interference performance existed in traditional detection algorithm of voltage sag of d-q detection algortihom and Hilbert detection algorithm, a new detection algorithm of voltage sag ...
TIAN Ming, WANG Chang-nan, HE Cheng
doaj  

Power quality disturbances assessment during unintentional islanding scenarios. A contribution to voltage sag studies [PDF]

open access: yes, 2019
This paper presents a novel voltage sag topology that occurs during an unintentional islanding operation (IO) within a distribution network (DN) due to large induction motors (IMs).
Bosch Tous, Ricardo   +2 more
core   +2 more sources

Molecular characterisation of human penile carcinoma and generation of paired epithelial primary cell lines

open access: yesMolecular Oncology, EarlyView.
Generation of two normal and tumour (cancerous) paired human cell lines using an established tissue culture technique and their characterisation is described. Cell lines were characterised at cellular, protein, chromosome and gene expression levels and for HPV status.
Simon Broad   +12 more
wiley   +1 more source

Simulation of Linear Feedback Control of D-Statcom for Voltage Sag Mitigation [PDF]

open access: yes, 2005
Recently, the demands of electrical supply by industries and domestics customers have increased tremendously. This is due to the increase of large loads which are sensitive in industries like semiconductor and the building of new housing estates ...
Zulkifli, Shamsul Aizam
core  

Transcriptional network analysis of PTEN‐protein‐deficient prostate tumors reveals robust stromal reprogramming and signs of senescent paracrine communication

open access: yesMolecular Oncology, EarlyView.
Combining PTEN protein assessment and transcriptomic profiling of prostate tumors, we uncovered a network enriched in senescence and extracellular matrix (ECM) programs associated with PTEN loss and conserved in a mouse model. We show that PTEN‐deficient cells trigger paracrine remodeling of the surrounding stroma and this information could help ...
Ivana Rondon‐Lorefice   +16 more
wiley   +1 more source

Design of a High-Performance High-Pass Generalized Integrator Based Single-Phase PLL

open access: yes, 2016
Grid-interactive power converters are normally synchronized to the grid using phase-locked loops (PLLs). The performance of the PLLs is affected by the non-ideal conditions in the sensed grid voltage such as harmonics, frequency deviations and dc offsets
John, Vinod, Kulkarni, Abhijit
core   +1 more source

Potential therapeutic targeting of BKCa channels in glioblastoma treatment

open access: yesMolecular Oncology, EarlyView.
This review summarizes current insights into the role of BKCa and mitoBKCa channels in glioblastoma biology, their potential classification as oncochannels, and the emerging pharmacological strategies targeting these channels, emphasizing the translational challenges in developing BKCa‐directed therapies for glioblastoma treatment.
Kamila Maliszewska‐Olejniczak   +4 more
wiley   +1 more source

ATF4‐mediated stress response as a therapeutic vulnerability in chordoma

open access: yesMolecular Oncology, EarlyView.
We screened 5 chordoma cell lines against 100+ inhibitors of epigenetic and metabolic pathways and kinases and identified halofuginone, a tRNA synthetase inhibitor. Mechanistically halofuginone induces an integrated stress response, with eIF2alpha phosphorylation, activation of ATF4 and its target genes CHOP, ASNS, INHBE leading to cell death ...
Lucia Cottone   +11 more
wiley   +1 more source

Model Predictive Control for Three-Phase, Four-Leg Dynamic Voltage Restorer

open access: yesEnergies
Dynamic voltage restores (DVRs) are usually used to mitigate the effect of voltage sag and guarantee sufficient power supply for sensitive loads. However, three-phase voltage cannot be compensated to the desired balance voltage under unbalanced three ...
Decan Liu   +3 more
doaj   +1 more source

Improving stability of utility-tied wind generators using dynamic voltage restorer

open access: yesJournal of Energy in Southern Africa, 2017
The generation of electricity using wind power is significantly increasing and has received considerable attention in recent years. One important problem with the induction generator based wind farms is that they are vulnerable to voltage disturbances ...
G Sivasankar, V Suresh Kumar
doaj   +1 more source

Home - About - Disclaimer - Privacy