Results 81 to 90 of about 7,315,995 (249)
Autonomous scanning probe microscopy and multi‐objective Bayesian optimization navigate a ternary (Al,Sc,B)N combinatorial library. Registered photoluminescence, electron‐probe compositional mapping, and X‐ray diffraction connect local electromechanical function to defect‐sensitive emission, composition, and crystal structure.
Yu Liu +12 more
wiley +1 more source
Engineered red blood cell‐derived extracellular vesicles (eRBCEVs) are synthesized via controlled microfluidic assembly from native RBC lipids, enabling tunable encapsulation of proteins, nucleic acids, nanoparticles, and viral vectors. The platform demonstrates reproducible nanoscale architecture, preserved membrane composition, and functional cargo ...
Chiranth K. Nagaraj +23 more
wiley +1 more source
A velocity induced eddy current probe has been used to detect cracks in both non-ferromagnetic and ferromagnetic metals. The simulation and experimental results show that this probe can successfully detect cracks in both cases, but further investigation ...
Bo Feng +3 more
doaj +1 more source
Gold‐stabilized copper suppresses hydroxide‐driven deactivation during anodic hydrogen evolution from furfural. Pairing this low‐potential anode with CO‐to‐ethylene electroreduction enables sub‐1 V operation at 400 mA cm−2, high single‐pass CO conversion, and co‐production of ethylene, furoic acid, and a separate hydrogen stream.
Sungjin Park +18 more
wiley +1 more source
Surface damage on honeycomb aircraft panels is often measured manually, and is therefore subject to variation based on inspection personnel. Eddy current testing (ECT) is sensitive to variations in probe-to-specimen spacing, or lift-off, and is thus ...
Tyler Reyno +4 more
doaj +1 more source
ABSTRACT We investigate the band alignment of a monocrystalline grafted p‐type Si/Ge0.89Sn0.11 heterostructure using X‐ray photoelectron spectroscopy (XPS). The bandgap of the Ge0.89Sn0.11 epilayer of 0.50 eV was first determined and cross‐verified using photoluminescence spectroscopy, infrared transmission, and theoretical calculation.
Yang Liu +11 more
wiley +1 more source
Temperature Drift Compensation of Eddy Current Sensor under High Temperature Environment
Eddy current sensor is an sensor based on eddy current effect. In practical engineering applications, the ambient temperature of eddy current sensor may be up to 135 ℃.
He Ping, Ma YunKai, Chen Hui
doaj +1 more source
Surrogate‐Optimized Flow‐Guided Miniature Condenser for Rapid Exhaled Glucose Detection
A surrogate‐optimized miniature condenser guides humid exhaled flow toward cold surfaces to accelerate exhaled breath condensate collection. By improving vapor access within a compact footprint, the design increases sample yield. This enables post‐collection enrichment and rapid colorimetric glucose detection from dilute exhaled biomarkers within a 5 ...
Yiming Thomas Lu +6 more
wiley +1 more source
An improved structure for axial-flux eddy current couplings with combined rectangleshaped magnets is proposed to minimize cogging torque without sacrificing torque density. Then, a novel analytical electromagnetic-thermal model, which takes the change of
Di Zheng +5 more
doaj +1 more source
Degradable Magnetic Composites from Recycled NdFeB Magnets for Soft Actuation and Sensing
This work presents a degradable soft magnetic composite made from recycled NdFeB particles embedded in a gelatin‐based organogel. The material is processed into magnetic sensors and soft robotic components, which can later be dissolved in a green solvent to recover NdFeB magnetic particles.
Muhammad Bilal Khan +14 more
wiley +1 more source