Results 1 to 10 of about 14,131,156 (297)
This study aimed to introduce an alternative, inexpensive, and straightforward polymer with specific mechanical and dielectric properties suitable for the fabrication of a clinical-grade kidney phantom.
Kamal Izdihar +5 more
doaj +1 more source
Rhizophora spp. wood has the potential to serve as a solid water or tissue equivalent phantom for photon and electron beam dosimetry. In this study, the effective atomic number (Zeff) and effective electron density (Neff) of raw wood and binderless ...
Mohammad W. Marashdeh +5 more
doaj +1 more source
Dopant Concentration and Effective Atomic Number of Copper-Doped Potassium Borate Glasses
Copper-doped (0.5 mol%) and undoped potassium borate glasses have been prepared by the composition of (100-x)H3BO3 + xK2CO3, where 10 ≤ x ≤ 30 mol % by the traditional melting quenching method. The structural pattern of glasses with different composition
I. Hossain, N. K. Shekaili, H. Wagiran
doaj +1 more source
Dual-Energy Computed Tomography For Differentiation Between Osteoblastic Metastases and Bone Islands
ObjectiveThe objective of our study was to evaluate the utility of Rho/Z on dual-energy computed tomography (DECT) for the differentiation of osteoblastic metastases (OBMs) from bone islands (BIs).MethodsDECT images of 110 patients with malignancies were
Chijie Xu, Lingling Kong, Xiaoyi Deng
doaj +1 more source
Determination of the effective atomic number: A theoretical justification
In this paper, we have tried to seek a theoretical justification for the effective atomic number for Compton scattering studies by computing it from free atom Hartree-Fock wave function based Compton profiles compiled by Biggs et al. Typical experimental examples have been provided which show a good agreement with that of theory justifying the validity
Sankarshan, B. M., Umesh, T. K.
openaire +1 more source
External Bremsstrahlung Studies on Films of Lead Monoxide Filled Polycarbonate Composite
The development of high-Z (high atomic number) radiation shielding materials is vital in order to protect personnel who work with harmful gamma radiation sources. At the same time, the emission of external bremsstrahlung (EB) radiation in those shielding
V. A. Kandagal, B. Lobo
doaj +1 more source
Effective atomic numbers, electron densities, and tissue equivalence of some gases and mixtures for dosimetry of radiation detectors [PDF]
Total mass attenuation coefficients, µm, effective atomic number, Zeff, and effective electron density, Neff, of different gases - carbon dioxide, methane, acetylene, propane, butane, and pentane used in radiation detectors, have been calculated for ...
Singh Vishwanath P., Badiger Nagappa M.
doaj +1 more source
Effective Atomic Number Determination of Rare Earth Oxides with Scattering Intensity Ratio
Effective atomic numbers () of scientific samples (rare earth) were determined experimentally by scattering of 59.54 keV gamma photons from 5 Ci 241Am annular radioactive source.
A. Turşucu, D. Demir, P. Önder
doaj +1 more source
Brachytherapy is a special case of radiotherapy. It should be arranged according to some principles in medical radiation applications and radiation physics.
Berkay Camgöz, Dilara Tarım
doaj +1 more source
Synthesized effective atomic numbers for commercially available dual-energy CT [PDF]
The objective of this study was to assess synthesized effective atomic number (Zeff) values with a new developed tissue characteristic phantom and contrast material of varying iodine concentrations using single-source fast kilovoltage switching dual-energy CT (DECT) scanner.A newly developed multi energy tissue characterisation CT phantom and an ...
Kawahara, Daisuke +6 more
openaire +4 more sources

