Results 71 to 80 of about 111,173 (172)

High-speed and accurate detection of high-impedance arcing faults in renewable energy microgrids using a master-slave ADALINE algorithm

open access: yesAin Shams Engineering Journal
High-Impedance Arcing Faults (HIAFs) in electrical microgrids are among the abnormal conditions that are difficult to detect by conventional protective devices due to low current and non-linear behavior. In addition, the behavioral similarity of HIAFs to
Mohsen Jannati, Hamidreza Toodeji
doaj   +1 more source

بررسی عوامل مؤثر بر اضافه ولتاژ گذرای ناشی از کلیدزنی کلید خلاء در شبکه توزیع و راهکار کاهش شدت آن [PDF]

open access: yesمجله مدل سازی در مهندسی
کلیدهای قدرت از هر نوعی که باشند، به عنوان یک منبع تولید اضافه ولتاژهای گذرا در سیستم‌های قدرت شناخته می‌شوند. در این بین، کلید‌های قدرت از نوع خلاء (Vacuum Circuit Breaker-VCB) اضافه ولتاژهای شدیدتری را نسبت به دیگر انواع کلیدها تولید می‌کنند.
احمد مرادی   +2 more
doaj   +1 more source

Analysis of Magnitude and Rate-of-rise of VFTO in 550 kV GIS using EMTP-RV

open access: yesJournal of Electrical Engineering and Technology, 2013
Very Fast Transients (VFT) originate mainly from disconnector switching operations in Gas Insulated Substations (GIS). In order to determine the rate-of-rise of Very Fast Transient Overvoltage (VFTO) in a 550 kV GIS, simulations are carried out using EMTP-RV.
Hun-Chul Seo   +5 more
openaire   +2 more sources

RV-C15 replication induces incomplete autophagy in HAE at 12hpi.

open access: yes, 2022
A: Fold change graph represents Lamp-1, LC3b-I, and LC3b-II protein levels normalized to the endogenous control (actin) and compared to non-infected cultures. Data shown are from two independent donors, represented by circles and triangles. Blot above is
Kelsey M. Gray (11567800)   +8 more
core   +1 more source

Novel Techniques to Reduce Transformer Inrush Current Using EMTP Software

open access: yesمهندسی مخابرات جنوب
Transformer inrush current is a high-amplitude, non-sinusoidal transient that occurs during initial energization, leading to voltage dips, power quality degradation, and relay misoperations.
Amir Ghaedi   +2 more
doaj  

Back-flashover Investigation of HV Transmission Lines Using Transient Modeling of the Grounding Systems

open access: yesIranian Journal of Electrical and Electronic Engineering, 2016
The article presents the transients analysis of the substation grounding systems and transmission line tower footing resistances which can affect to the back-flashover (BF) or overvoltage across insulator chain in an HV power systems by using EMTP-RV ...
F. Amanifard, N. Ramezani
doaj  

Modellizzazione di celle Na-Beta per l'accumulo elettrochimico stazionario [PDF]

open access: yes, 2014
Costruzione di modelli in EMTP-RV delle celle, moduli, unità delle batterie sodio-zolfo e delle sodio-cloruro di nichel. Costruzione dei modelli dei convertitori in EMTP-RV dei sistemi di accumulo sulla rete di trasmissione (150 ...
Benetti, Riccardo
core  

Evaluating the High Frequency Behavior of the Modified Grounding Scheme in Wind Farms

open access: yesApplied Sciences, 2017
Wind generators are exposed to numerous destructive forces such as lightning and are therefore vulnerable to these phenomena. To evaluate the transient behavior of a wind power plant during direct and indirect strikes, modeling of all relevant components
Seyede Fatemeh Hajeforosh   +3 more
doaj   +1 more source