Pemodelan Dan Analisa Perlindungan Gardu Induk Dari Sambaran Petir Langsung Di PT.PLN(Persero) Gardu Induk 150kv Sukolilo-Surabaya Menggunakan Perangkat Lunak EMTP-RV [PDF]
Peralatan yang berada di gardu induk rentan tersambar petir karena berada diruang terbuka. Sehingga diperlukan sistem perlindungan petir eksternal untuk memberikan perlindungan kepada bangunan dan peralatan sistem tenaga listrik dari sambaran petir ...
I Gd. A. Widya W.S.,, I Gd. A. Widya W.S.,
core
Waveform-Level EMT Analysis of Overhead–Cable Transition Effects in Hybrid Transmission Corridors
Hybrid transmission corridors combining overhead lines and underground cables introduce impedance discontinuities that significantly modify electromagnetic transient behavior.
Luis Salazar Fonseca +6 more
doaj +1 more source
Subsynchronous Resonance and FACTS-Novel Control Strategy for Its Mitigation
The subsynchronous resonance (SSR) is an important problem in the power system, and especially the series compensated transmission lines may cause SSR in the turbine generators, such that it leads to the electrical instability at subsynchronous ...
Doan Duc Tung, Le Van Dai, Le Cao Quyen
doaj +1 more source
Analysis of transmission line modeling routines by using offsets measured least squares regression ant lion optimizer in ORPD and ELD problems. [PDF]
Chary GVB, Rosalina KM.
europepmc +1 more source
EMTP-RV investigation of a Mho relay model for protection of 500 kV series compensated transmission lines [PDF]
Extra High Voltage (EHV) transmission lines are designed to transfer large amounts of electrical power from one place to another. The lines being left open to the environment (wind and bad weather) constitute a major reason for incidence of faults on the
Shah, Abhaykumar Babulal
core +1 more source
This paper proposes a novel single-ended traveling wave-based fault location method for unearthed overhead lines with a complex topology. The low fault current magnitudes of a phase-to-ground fault in unearthed sub-transmission networks make ineffective ...
Sebastian Dambone Sessa +5 more
doaj +1 more source
35 kV系统中铁磁谐振过电压频繁发生,对系统造成很大的危害。利用理论分析和EMTP-RV仿真相结合的方法,分析了中国35 kV系统3种中性点接地方式(中性点不接地、经消弧线圈或小电阻接地)下由电磁式电压互感器(PT)饱和引起的铁磁谐振过电压,研究结果表明,在中性点经消弧线圈或小电阻接地系统中,只要消弧线圈或小电阻的参数选取合适,能够将中性点位移电压限制在电压三角形内,可有效抑制铁磁谐振的发生。
汪伟 +6 more
doaj
An efficient deep learning based scheme for adaptive auto-reclosing in power transmission lines
As a large percentage of faults in transmission lines are single-line-to-ground (SLG) and transient in nature, the use of adaptive single-phase auto-reclosing (ASPAR) schemes is essential.
Farhad Hatami Aloghareh +2 more
doaj +1 more source
Estimation of Current Distribution in the Electric Railway System in the EMTP-RV
Current distribution is important for the electromagnetic compatibility and electromagnetic fields calculations. The current value directly determines the magnetic field and consequently coupling of the systems. The return current has an opposite direction of supply current and decreases coupling and interferences.
Milešević, Boško +2 more
openaire +1 more source
Risk Analysis of Energy Systems Integrated With Renewable Energy Resources
The switching surges that arising due to integrating renewable energy resources with power grids have become the major factor in the insulation coordination of the power systems. Consequently, it is urgent to perform proper risk analysis of the switching
Samy M. Ghania
doaj +1 more source