Results 81 to 90 of about 141 (133)
Some of the next articles are maybe not open access.
Modeling of a Chain Link Statcom in EMTP-RV
2006 Canadian Conference on Electrical and Computer Engineering, 2006This paper describes an alternative circuit arrangement to form a static synchronous compensator (STATCOM), by connecting a number of gate turn off (GTO) thyristor converter 'chain links' in series per phase on the AC side of the system. Each GTO converter forms one 'link' of a 1-phase bridge voltage-sourced converter (VSC) and is referred to as a ...
N. M. Shah +2 more
openaire +1 more source
Estimation of current distribution in the electric railway system in the EMTP-RV
Electric Power Systems Research, 2018Current distribution in the electric traction system is an important factor regarding the electromagnetic influences on the surrounding metallic structures. The current value directly determines the magnetic field and consequently coupling of the systems. A single rail traction system can be equipped with return conductor.
Bosko Milesevic +3 more
openaire +1 more source
Simulation of electromagnetic transients with EMTP-RV
2015This chapter presented a summary on numerical methods used in EMTP (EMTPRV version) for the computation of electromagnetic transients. EMTP offers several options and modules for the simulation and analysis of complex power systems. EMTP offers a unified environment that can be applied to study power systems from steady-state conditions, to ...
J. Mahseredjian +3 more
openaire +2 more sources
Indirect effects of lightning on wind turbines using EMTP-RV
2011 International Conference on Power Engineering, Energy and Electrical Drives, 2011This paper is concerned with the protection of wind turbines against the indirect effects of lightning. Lightning damages involving wind turbines have come to be regarded with increasing concern. The wind power generation is rapidly growing in Portugal, but still there are few studies regarding the lightning protection of wind turbines using models of ...
R. B. Rodrigues +2 more
openaire +1 more source
Research on lightning overvoltage in Ecuador 230kV GIS substation based on EMTP-RV
2021 IEEE 4th International Electrical and Energy Conference (CIEEC), 2021The simulation model of a new 230 kV GIS substation in Ecuador was established by EMTP-RV. The lightning overvoltage levels of the main equipment in the substation under different modes of thunder wave invasion, different tower and substation operation are calculated, and the insulation coordination of each equipment is checked.
Gong Chen +3 more
openaire +1 more source
Power Factor Correction Using EMTP-RV for Engineering Education
2019 54th International Universities Power Engineering Conference (UPEC), 2019Power quality is one of the major requirements in power system operation and design. A power factor that is close to one is a good indicator for the overall power quality, especially for an electrical power system with high uptake of commercial loads with a large amount of inductance.
Denisa Stet +5 more
openaire +1 more source
Modeling, control and simulation of a chain link STATCOM in EMTP-RV
Electric Power Systems Research, 2009Abstract This paper describes an alternative STATic synchronous COMpensator (STATCOM), by connecting a number of gate turn off (GTO) thyristor converters in series on the ac side of the system. Each GTO converter forms one ‘link’ of a 1-phase, full-bridge voltage–source-converter (VSC) and is referred to as a ‘Chain Link Converter’ (CLC). Each GTO of
Nikunj M. Shah +2 more
openaire +1 more source
Dynamic analysis of Microturbine and FuelCell in MicroGrid using EMTP-RV
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers, 2010The Microsource has to supply high quality Power that has high reliability and high energy efficiency to Load according to operating type of Microgrid. The energy sources of microsource type have various dynamic characteristic and transient response corresponding to classes and application skill.
Gyu-Seok Seo, Jae-Hyun Ju
openaire +1 more source
Modeling of Inverter-Based Resources Using Equivalent Current Sources in EMTP-RV
2020 IEEE Power & Energy Society General Meeting (PESGM), 2020This paper presents a time-domain, equivalent current source model (CSM) for inverter-based resources in EMTPRV for evaluating their harmonic impacts, behavior, and interactions with the grid. Whereas detailed inverter models can be accurate if the inverter design and parameters are precisely known, their simulations are time-consuming.
Soham Roy +3 more
openaire +1 more source
An Advanced Interface Between the LIOV Code and the EMTP-RV
2008Accurate evaluation of the response of overhead distribution lines to lightning electromagnetic pulse (LEMP) represents an important aspect in insulation coordination of distribution networks. The improvement of the accuracy of such an analysis calls for the extension of the field-to-transmission line coupling models from single straight lines to multi-
NAPOLITANO, FABIO +5 more
openaire +3 more sources

