Results 21 to 30 of about 10,503 (121)
ABSTRACT The Clinical and Laboratory Standards Institute M100 document serves as a cornerstone standard for clinical microbiology laboratories in China. Maintaining the scientific rigor of its predecessors, the 36th edition incorporates updated epidemiological cutoff values, pharmacokinetic/pharmacodynamic data, and clinical efficacy evidence to revise
Kanghong Xu, Qi Wang, Hui Wang
wiley +1 more source
ABSTRACT Background Non‐typeable Streptococcus pneumoniae (NT‐Sp) strains lack detectable capsules and are often missed by traditional serotyping. While associated primarily with asymptomatic carriage, NT‐Sp has emerged as a key player in antimicrobial resistance (AMR) gene dissemination and serotype replacement in the post‐vaccine era. This systematic
Robert K. Reeks +2 more
wiley +1 more source
We investigated the in vitro activity of amphotericin B, fluconazole, and itraconazole against clinical Trichosporon asahii isolates (n = 43) by NCCLS M27A reference microdilution method and explored the correlation between Etest and NCCLS reference ...
Hascelik, G, Arikan, S
core +1 more source
Abstract Background Vancomycin is first‐line treatment for methicillin‐resistant Staphylococcus aureus (MRSA) infections. However, despite guideline recommendations, there is no evidence that targeting vancomycin trough concentrations of ≥15 mg/L in children confers clinical benefit and is associated with vancomycin‐associated nephrotoxicity (VAN ...
Megan R. Nettleton +11 more
wiley +1 more source
Gonococcal Peritonitis Complicated by Intraperitoneal Abscess and Pleural Empyema: A Case Report
ABSTRACT This report presents a unique case of gonococcal peritonitis complicated by an intraperitoneal abscess and pleural effusion in a 52‐year‐old woman with liver cirrhosis. No bacteriologically confirmed genital infection was identified, and the route of infection could not be established.
Hanne Rheder Ellegaard Mikkelsen +3 more
wiley +1 more source
TCG‐CMDA, a machine learning‐guided capillary microfluidic design automation platform, enables automated design of tree‐shaped concentration gradient generators for programmable mixing of two agents. The pump‐free chip supports synchronized passive flow and programmable gradient formation, providing a practical framework for decentralized point‐of‐care
Mahmood Khalghollah +4 more
wiley +1 more source
La Prueba Épsilon (Etest) es un método con una base de agar para evaluar susceptibilidad microbiana, desarrollado para vencer las desventajas de la difusión en disco y los métodos de dilución convencional, mientras mantiene los aspectos favorables de ...
Jaramillo Velásquez, Sergio
core +1 more source
Abstract The Qualified Presumption of Safety (QPS) process was developed to provide a harmonised safety assessment approach to support EFSA Scientific Panels and Units. The QPS approach assesses the taxonomic identity, body of knowledge and safety of microorganisms intentionally added to the food and feed chain.
EFSA Panel on Biological Hazards (BIOHAZ) +26 more
wiley +1 more source
The susceptibility of 513 clinical isolates to doripenem was determined by broth microdilution, agar dilution, and Etest. Overall agreements for Etest and agar dilution MIC values compared to reference broth microdilution at ±1 log 2
R. Flamm +4 more
core +1 more source
This study in Northwestern Ethiopia analysed M. haemolytica in pneumonic sheep and identified 23 M. haemolytica isolates from 140 nasal swab samples. M. haemolytica isolates were sensitive to most drugs, including tetracycline, chloramphenicol, gentamicin, streptomycin, kanamycin and ampicillin.
Fanuel Bizuayehu Yihunie +6 more
wiley +1 more source

