Results 51 to 60 of about 1,942,616 (166)
A compatmental model of an External Urethral Sphincter Motoneuron of Onuf's Nucleus
This article discusses a model of the electrical behavior of an external urethral sphincter motoneuron, based on morphological parameters like soma size, dendritic diameters and spatial dendritic configuration, and several electrical parameters.
Vanderschoot, J. +6 more
core +1 more source
A canine model of reversible urethral sphincter insufficiency
This study developed an animal model with internal and external urethral sphincter insufficiency by bypassing the sphincter without major damage so that the animal under study can return to normal life after the study.
Pourya Shokri +5 more
doaj +1 more source
Zeroing Pressures in Urodynamics: Revisiting Current Practice and Pressure Interpretation
ABSTRACT Introduction Zeroing of pressure transducers is a fundamental step in urodynamic testing, as it affects pressure tracings and numerical values. Atmospheric zeroing before catheter insertion is the recommended approach, but zeroing with catheters in situ is also used.
Lucas Antonio Pereira do Nascimento +3 more
wiley +1 more source
Sudden, Painless Incontinence following Extracorporeal Shock Wave Lithotripsy: A Case Report
Urinary incontinence is a stent-related complication; however, total incontinence is not often seen in emergency departments. We report a patient who presented with a sudden, painless, and total urinary incontinence after extracorporeal shock wave ...
Fatih Akbulut +2 more
doaj +1 more source
ABSTRACT Aims To assess 1‐year Transcutaneous Tibial Nerve Stimulation (TTNS) treatment persistence in routine clinical care and to explore clinical and urodynamic factors associated with treatment persistence in patients with lower urinary tract dysfunction (LUTD).
Damien Prat +9 more
wiley +1 more source
To review the postoperative results and complications associated with urethral sphincter mechanism incompetence managed with a static hydraulic urethral ...
Delisser, P J +3 more
core +1 more source
ABSTRACT Introduction For more than four decades, the AMS‐800 has remained the clinical benchmark device for the treatment of male stress urinary incontinence (SUI). Although it remains the gold standard for male SUI, the AMS‐800 has continued to have limitations such as suboptimal post‐operative continence rates, fixed hydraulic pressure, need for ...
Erin C. Schnell +2 more
wiley +1 more source
AIMS This functional urodynamic study assessed the effect of the nitric oxide donor isosorbide dinitrate on the external urethral sphincter and hypothesised first that nitric oxide could lower the resting sphincter pressure, second that nitric oxide ...
Bretscher S +5 more
core +1 more source
Development and Validation of Urodynamic Report Writer: A Chat GPT App
ABSTRACT Objective Accurate interpretation and reporting of urodynamic studies are essential for diagnosis and management of lower urinary tract dysfunction, yet remain time‐consuming and operator‐dependent. To develop and validate the Urodynamic Report Writer App (URapp), a GPT‐4o‐based virtual assistant that supports interpretation of clinician ...
Riccardo Lombardo +16 more
wiley +1 more source
SIMULTANEOUS MEASUREMENT OF CYSTOMETRY AND ELECTROMYOGRAPHY OF EXTERNAL URETHRAL SPHINCTER [PDF]
Simultaneous measurement of cystometry and electromyography of external urethral sphincter was performed on sixty five cases (54 male, II female), and the comparative studies of detrusor pressure to total vesical pressure was done in the cystometric ...
長谷川, 信雄
core