Results 31 to 40 of about 12,040 (193)

Study on the relationship between the characteristics of water droplets on the shed of composite insulators and the pollution flashover voltage

open access: yesEnergy Reports, 2022
The anti-pollution flashover characteristic of composite insulators is the main indicators to evaluate their electrical performance, and the pollution flashover voltage can directly characterize the anti-pollution flashover characteristics of the ...
Wei Wang   +7 more
doaj   +1 more source

Surface flashover of silicon

open access: yesIEEE Transactions on Electron Devices, 1990
Empirical information about surface flashover of silicon in a vacuum ambient which shows that in breakdown the current is carried primarily inside the semiconductor is presented. This observation shows that the physical processes responsible for flashover of silicon are fundamentally different from those assumed in the standard model for flashover of ...
Peterkin, Frank E.   +7 more
openaire   +3 more sources

AC Flashover Performance of 10 kV Rod-Plane Air-Gapped Arresters under Rain Conditions

open access: yesEnergies, 2018
According to operational experience of power systems, the outdoor insulation strength can be reduced due to the effect of rain. Till now, little work has been done to investigate the flashover performance of air gapped arresters under rain conditions ...
Jiazheng Lu   +4 more
doaj   +1 more source

External Insulation Performance under DC Voltages of Polluted Post Insulators for Power Stations in Rainy Weather: A Brief Review and Recent Progress

open access: yesEnergies
The discharge and flashover phenomenon of post insulators in rainy weather has not been given sufficient consideration; however, with the construction of ultra-high voltage power grids, the performance of the external insulation and the ability to ...
Yuxi Dong   +7 more
doaj   +1 more source

DC Flashover Dynamic Model of Post Insulator under Non-Uniform Pollution between Windward and Leeward Sides

open access: yesEnergies, 2019
Experience shows that under unidirectional wind or certain terrain, the surface of post insulators is non-uniformly polluted between windward and leeward sides, which affects the flashover characteristics.
Zhijin Zhang   +5 more
doaj   +1 more source

Enhancing flashover strength along oil/pressboard interface using nanofluids

open access: yesAlexandria Engineering Journal, 2020
One of the weakest paths for electrical discharge in power transformers is oil/pressboard interface. So, in this study it is aimed to enhance the flashover resistance of such interface through using the concept of nanofluids.
El-Sayed M. El-Refaie   +3 more
doaj   +1 more source

Testing for knowledge : maximising information obtained from fire tests by using machine learning techniques [PDF]

open access: yes, 2019
A machine learning (ML) algorithm was applied to predict the onset of flashover in 1:5 scale Room Corner Test experiments with sandwich panels. Towards this end, a penalized logistic regression model was chosen to detect the relevant variables and ...
Dexters, Arjan   +4 more
core   +1 more source

Monitoring contamination level on insulator materials under dry condition with a microwave reflectometer [PDF]

open access: yes, 2016
Current techniques used for monitoring the levels of contamination on high voltage insulators, such as leakage current and infrared, are not effective in dry conditions since they require the surface of the insulator to be wetted by fog, rain or snow. If
Jiang, Y.   +5 more
core   +1 more source

Effect of equivalent salt deposit density on flashover voltage of contaminated insulator energized by HVDC [PDF]

open access: yes, 2000
In Malaysia, the demand for electric power is increasing day by day due to more consumption of power in the industrial sector. Recently, the high voltage DC transmission lines are under construction near the coastal environments for transmitting the ...
Ahmad, H.   +6 more
core  

Study on Influencing Factors of Insulators Flashover Characteristics on the 110 kV True Tower Under the Lightning Impulse

open access: yesIEEE Access, 2018
Lightning strike is the main reason for the transmission line tripping. Studies on the insulator flashover characteristics and the accurate flashover criteria under the lightning impulse are the basis for correctly evaluating the lightning resistance ...
Yongxia Han   +7 more
doaj   +1 more source