Results 31 to 40 of about 1,193 (116)
Simulation Experiment on Discharge of Plastic Film Overlapping on UHVDC Transmission Lines
In order to study the discharge phenomena of plastic film overlapping on UHV DC transmission lines and explore the cause of flashover fault of a ± 800 kV UHV line, an experimental study is conducted on the flashover characteristics of plastic film with ...
Shenghui WANG +3 more
doaj +1 more source
Wet Snow Flashover Characteristics of 500-kV AC Insulator Strings with Different Arrangements
In order to study the wet snow flashover characteristics of 500-kV AC insulator strings under different arrangements, wet snow flashover tests were carried out in the large climate chamber of China Electric Power Research Institute (CEPRI).
Jingwei Xu +7 more
doaj +1 more source
The anti-pollution flashover characteristic of composite insulators is the main indicators to evaluate their electrical performance, and the pollution flashover voltage can directly characterize the anti-pollution flashover characteristics of the ...
Wei Wang +7 more
doaj +1 more source
AC Flashover Performance of 10 kV Rod-Plane Air-Gapped Arresters under Rain Conditions
According to operational experience of power systems, the outdoor insulation strength can be reduced due to the effect of rain. Till now, little work has been done to investigate the flashover performance of air gapped arresters under rain conditions ...
Jiazheng Lu +4 more
doaj +1 more source
The discharge and flashover phenomenon of post insulators in rainy weather has not been given sufficient consideration; however, with the construction of ultra-high voltage power grids, the performance of the external insulation and the ability to ...
Yuxi Dong +7 more
doaj +1 more source
Experience shows that under unidirectional wind or certain terrain, the surface of post insulators is non-uniformly polluted between windward and leeward sides, which affects the flashover characteristics.
Zhijin Zhang +5 more
doaj +1 more source
Flame‐retardant bio‐based thermo‐flexible phase‐change composites for advanced battery thermal management. Batteries face critical challenges in thermal management, including overheating risks, poor interfacial contact, and mechanical vibration–induced performance attenuation.
Shichao Feng +7 more
wiley +1 more source
Experimental Investigation of Burning Liquids in Reduced Oxygen
ABSTRACT The effects of oxygen concentration on combustion of gases have been investigated on fundamental levels in several studies. However, the same type of fundamental studies has not been made for liquid or solid fuels due to complex relationships between flame structure and changing mass loss rates (MLR).
Joakim Åström +3 more
wiley +1 more source
Enhancing flashover strength along oil/pressboard interface using nanofluids
One of the weakest paths for electrical discharge in power transformers is oil/pressboard interface. So, in this study it is aimed to enhance the flashover resistance of such interface through using the concept of nanofluids.
El-Sayed M. El-Refaie +3 more
doaj +1 more source
Effecft of co‐doping polyaniline with phosphoric acid and phytic acid on the heat release rate of polyethylene. Abstract Polyolefins, such as polyethylene (PE), are highly flammable and electrically insulative, limiting their applicability. The study explored the flame‐retardancy and electrical conductivity of PE/polyaniline (PE/PANI) nanocomposites ...
Akeem Adisa +4 more
wiley +1 more source

