Results 31 to 40 of about 12,040 (193)
The anti-pollution flashover characteristic of composite insulators is the main indicators to evaluate their electrical performance, and the pollution flashover voltage can directly characterize the anti-pollution flashover characteristics of the ...
Wei Wang +7 more
doaj +1 more source
Empirical information about surface flashover of silicon in a vacuum ambient which shows that in breakdown the current is carried primarily inside the semiconductor is presented. This observation shows that the physical processes responsible for flashover of silicon are fundamentally different from those assumed in the standard model for flashover of ...
Peterkin, Frank E. +7 more
openaire +3 more sources
AC Flashover Performance of 10 kV Rod-Plane Air-Gapped Arresters under Rain Conditions
According to operational experience of power systems, the outdoor insulation strength can be reduced due to the effect of rain. Till now, little work has been done to investigate the flashover performance of air gapped arresters under rain conditions ...
Jiazheng Lu +4 more
doaj +1 more source
The discharge and flashover phenomenon of post insulators in rainy weather has not been given sufficient consideration; however, with the construction of ultra-high voltage power grids, the performance of the external insulation and the ability to ...
Yuxi Dong +7 more
doaj +1 more source
Experience shows that under unidirectional wind or certain terrain, the surface of post insulators is non-uniformly polluted between windward and leeward sides, which affects the flashover characteristics.
Zhijin Zhang +5 more
doaj +1 more source
Enhancing flashover strength along oil/pressboard interface using nanofluids
One of the weakest paths for electrical discharge in power transformers is oil/pressboard interface. So, in this study it is aimed to enhance the flashover resistance of such interface through using the concept of nanofluids.
El-Sayed M. El-Refaie +3 more
doaj +1 more source
Testing for knowledge : maximising information obtained from fire tests by using machine learning techniques [PDF]
A machine learning (ML) algorithm was applied to predict the onset of flashover in 1:5 scale Room Corner Test experiments with sandwich panels. Towards this end, a penalized logistic regression model was chosen to detect the relevant variables and ...
Dexters, Arjan +4 more
core +1 more source
Monitoring contamination level on insulator materials under dry condition with a microwave reflectometer [PDF]
Current techniques used for monitoring the levels of contamination on high voltage insulators, such as leakage current and infrared, are not effective in dry conditions since they require the surface of the insulator to be wetted by fog, rain or snow. If
Jiang, Y. +5 more
core +1 more source
Effect of equivalent salt deposit density on flashover voltage of contaminated insulator energized by HVDC [PDF]
In Malaysia, the demand for electric power is increasing day by day due to more consumption of power in the industrial sector. Recently, the high voltage DC transmission lines are under construction near the coastal environments for transmitting the ...
Ahmad, H. +6 more
core
Lightning strike is the main reason for the transmission line tripping. Studies on the insulator flashover characteristics and the accurate flashover criteria under the lightning impulse are the basis for correctly evaluating the lightning resistance ...
Yongxia Han +7 more
doaj +1 more source