Results 21 to 30 of about 3,740,152 (255)

Diverter operation characteristics simulation and uncertainty analysis of lead- bismuth flowmeter calibration facilities

open access: yesHe jishu, 2023
BackgroundInstitute of Modern Physics, Chinese Academy of Sciences is developing a high-precision calibration device for lead-bismuth flowmeters based on the static mass method.
ZHU Yucheng   +5 more
doaj   +1 more source

Abstract Number ‐ 82: Central Retinal Artery Metallic Embolus After Ophthalmic Segment Internal Carotid Artery Aneurysm Flow‐diverter Embolization

open access: yesStroke: Vascular and Interventional Neurology, 2023
Introduction Flow‐diverting stents are effective devices in treating what would have previously been difficult to treat aneurysms such as wide‐necked, fusiform, blood blister, or giant aneurysms.
Thymur A Chaudhry, David Niemann
doaj   +1 more source

Successful Treatment of Giant Intracranial Aneurysm Using Flow-Diverter Device: First Experience in Nepal

open access: yesJournal of Nepal Health Research Council, 2020
Giant intracranial aneurysms are defined as aneurysms that measure over 25 mm in the greatest dimension. They are rare vascular lesions that preferentially involve regions with high-velocity blood flow, such as the cavernous and supraclinoid segments of ...
Subash Phuyal   +4 more
doaj   +1 more source

Internal Carotid Artery Reconstruction with a “Mega Flow Diverter”: First Experience with the 6×50 mm DERIVO Embolization Device [PDF]

open access: yesNeurointervention, 2018
Endoluminal reconstruction with a flow diverter device has emerged as a viable and often preferable alternative to traditional techniques for the treatment of intracranial aneurysms.
Mario Martínez-Galdámez   +6 more
doaj   +1 more source

Optimization of flow diverters for cerebral aneurysms [PDF]

open access: yesJournal of Computational Science, 2012
Abstract A modern technique to treat cerebral aneurysms is to insert a flow diverter in the parent artery. In order to produce an optimal design of such devices, we consider a methodology combining simulated annealing optimization and lattice Boltzmann simulations.
Hitomi Anzai   +3 more
openaire   +3 more sources

Nursing care of 22 patients with complex intracranial aneurysms treated with flow-diverting stents: A retrospective study

open access: yesJournal of Interventional Medicine, 2019
Objective: To summarize the nursing treatment of patients who underwent implantation of a blood flow diverter to treat complex intracranial aneurysms. Methods: Data from 22 patients with complex aneurysms, diagnosed at an interventional center for blood ...
Wenli Zhao   +3 more
doaj   +1 more source

Effect of Flow Diverter Porosity on Intraaneurysmal Blood Flow [PDF]

open access: yesClinical Neuroradiology, 2009
Growth and rupture, the two events that dominate the evolution of an intracranial aneurysm, are both dependent on intraaneurysmal flow. Decrease of intraaneurysmal flow is considered an attractive alternative for treating intracranial aneurysms by minimally invasive techniques.
Luca, Augsburger   +6 more
openaire   +3 more sources

Compacting a Single Flow Diverter versus Overlapping Flow Diverters for Intracranial Aneurysms: A Computational Study [PDF]

open access: yesAmerican Journal of Neuroradiology, 2017
Locally compacting the mesh of a flow diverter by a dynamic push-pull technique can accelerate intracranial aneurysm healing. We asked how this deployment strategy compares with overlapping 2 flow diverters for aneurysmal flow reduction.Using a high-fidelity virtual stent placement method, we simulated 3 flow-diverter strategies (single noncompacted, 2
R.J. Damiano   +6 more
openaire   +2 more sources

Coiling Techniques in management of Cerebral Aneurysms Preoperative assessment, Outcome and Complications [PDF]

open access: yesMinia Journal of Medical Research, 2019
Background: according to the International Subarachnoid Trial (ISAT), patients with subarachnoid hemorrhage (SAH) fared better with endovascular coiling than those with surgical clipping (Molyneux et al., 2005).
Ahmed Khafagy   +3 more
doaj   +1 more source

Intracranial aneurysms treatment using new generation FRED X flow diverters with antithrombotic coating and preoperative PreSize Neurovascular software simulation: literature review and own clinical observations analysis

open access: yesUkrainian Neurosurgical Journal, 2023
Objective: Evaluate the possibilities of treating giant intracranial aneurysms and complex anatomy aneurysms by implanting new generation of FRED X flow diverters (MicroVention, USA) with antithrombogenic surface subject to preoperative ...
Yurii V. Cherednychenko   +5 more
doaj   +1 more source

Home - About - Disclaimer - Privacy