Results 41 to 50 of about 3,740,152 (255)

Microstructured Thin Film Nitinol for a Neurovascular Flow-Diverter [PDF]

open access: yes, 2016
A cerebral aneurysm occurs as a result of a weakened blood vessel, which allows blood to flow into a sac or a ballooned section. Recent advancement shows that a new device, ‘flow-diverter’, can divert blood flow away from the aneurysm sac.
Cheon, Seongsik   +5 more
core   +1 more source

The Importance of Wall Apposition in Flow Diverters

open access: yesNeurosurgery, 2018
Abstract BACKGROUND It is assumed that high pore densities in flow diverters (FDs) are beneficial for intracranial aneurysm (IA) healing. However, various animal studies are not conclusive on the issue, suggesting that other factors are in play. One important factor might be wall apposition.
Aquarius, Rene   +7 more
openaire   +5 more sources

Failure of Flow Diverter Treatment of Intracranial Aneurysms Related to the Fetal-type Posterior Communicating Artery [PDF]

open access: yesNeurointervention, 2015
PurposeThe pipeline embolization device (PED) is a flow diverter that has shown promise in the treatment of intracranial aneurysms. Close to one-fifth of aneurysms, however, fail to occlude after PED placement.
Anderson Chun On Tsang   +5 more
doaj   +1 more source

Intraluminal Flow Diverter Design Primer for Neurointerventionalists. [PDF]

open access: yes
The clinical use of flow diverters for the treatment of intracranial aneurysms has rapidly grown. Consequently, the market and technology for these devices has also grown.
Schaffer, Jeremy   +6 more
core   +1 more source

Impact of Age on the Diagnostic Yield of Routine EEG in People With Childhood or Juvenile Absence Epilepsy: A Cross‐Sectional Study

open access: yesAnnals of Clinical and Translational Neurology, EarlyView.
ABSTRACT Background We aimed to identify the proportion of individuals with a confirmed diagnosis of childhood absence epilepsy (CAE) or juvenile absence epilepsy (JAE) who show a negative routine EEG (rEEG), and to determine the main factors associated with this finding.
Francesco Fortunato   +7 more
wiley   +1 more source

Which spring is the best? Comparison of methods for virtual stenting. [PDF]

open access: yes, 2014
This paper presents a methodology for modeling the deployment of implantable devices used in minimally invasive vascular interventions. Motivated by the clinical need to perform preinterventional rehearsals of a stent deployment, we have developed ...
Spranger, K, Ventikos, Y
core  

Conformational Switching of Proteins on Material Surfaces Enabled by Peptide‐Oriented Adsorption

open access: yesAdvanced Functional Materials, EarlyView.
Responsive biointerfaces could be achieved using conformationally responsive proteins; however, their interconversion can be lost upon surface adsorption. Herein, we demonstrate that the incorporation a Au binding peptide into calmodulin allows for binding control on Au wherein the protein retains conformational switching. This capability was confirmed
Sakthirupini Ramamurthy   +7 more
wiley   +1 more source

Blood flow in intracranial aneurysms treated with Pipeline embolization devices: computational simulation and verification with Doppler ultrasonography on phantom models [PDF]

open access: yesUltrasonography, 2015
Purpose: The aim of this study was to validate a computational fluid dynamics (CFD) simulation of flow-diverter treatment through Doppler ultrasonography measurements in patient-specific models of intracranial bifurcation and side-wall aneurysms. Methods:
Anderson Chun On Tsang   +7 more
doaj   +1 more source

STUDY OF BLOOD FLOW VARIATION USING ANEURYSMFLOW SOFTWARE AFTER STENT FLOW DIVERTER APPLICATION

open access: yes, 2023
openStudio del cambiamento di flusso nell’aneurisma cerebrale post impianto di Flow Diverter. Introduzione: Uno dei metodi di trattamento degli aneurismi cerebrali avviene utilizzando stent a deviazione di flusso (Flow Diverter) i quali escludono l ...
VUKOVIC, SINISA
core  

A New Strategy for Creating Quantum Light Emitters Via Post‐Growth Hydrogen‐Ion Irradiation of III‐V Nanowires

open access: yesAdvanced Functional Materials, EarlyView.
A post‐growth method is demonstrated to realize energy‐tunable quantum emitters in GaAs/GaAsN/GaAs core–multishell nanowires on a Si substrate. By combining the N‐induced bandgap reduction with H‐ion irradiation, the GaAsN potential landscape is engineered, enabling isolated, narrow emission lines that function as single‐photon sources with g(2)(0) ∼ 0.
Akant Sagar Sharma   +10 more
wiley   +1 more source

Home - About - Disclaimer - Privacy