Results 31 to 40 of about 3,683 (163)

Tapered flow diverters in the treatment of intracranial aneurysms [PDF]

open access: yesTurkish Neurosurgery, 2016
To report the initial experience of cerebral aneurysm treatment with Tapered flow diverters (TFDs).Thirty patients with 34 aneurysms underwent cerebral aneurysm treatment with TFD (Silk, Balt, Montmorency, France) between March 2011 and March 2016. Procedural findings, complications, clinical and imaging follow-up were assessed retrospectively.The ...
Ahmet Peker   +6 more
openaire   +3 more sources

Incidence and Outcomes of Flow Diverter Braid Deformation following Treatment with Non-DFT Wire Devices

open access: yesNeurologia Medico-Chirurgica
Flow diverter braid deformation is occasionally observed after flow diverter placement. However, the frequency and clinical significance of flow diverter braid deformation in non-drawn filled tube wire devices remain unclear.
Shoko FUJII   +6 more
doaj   +1 more source

Flow diverter-coil technique for endovascular treatment of complex wide neck brain aneurysms, Technical point

open access: yesCaspian Journal of Internal Medicine, 2021
Background: Treatment of complex wide neck brain aneurysms is a challenging era in neurosurgery. Both surgical and endovascular therapies are considered for treatment of them. In endovascular, there are different ways such as trapping, coiling, stent and
Mohammad Ghorbani   +5 more
doaj  

Experience of implantation of flow-diverter in the acute period of aneurismatic intracranial hemorrhage

open access: yesЕндоваскулярна нейрорентгенохірургія, 2020
In the period from 2013 to 2019 at the Scientific and Practical Center for Endovascular Neuroradiology of the National Academy of Medical Sciences of Ukraine, implantation of flow-diverter in the acute period of aneurysmal intracranial hemorrhage was ...
D.V. Shchehlov   +4 more
doaj   +1 more source

The FRED-X Flow Diverter-An Australian Experience. [PDF]

open access: yesJ Med Imaging Radiat Oncol
ABSTRACTBackgroundThe FRED X flow diverter features antithrombotic surface treatment to reduce thrombogenicity. This study evaluated the safety and efficacy of FRED X in treating intracranial aneurysms in the Australian setting.MethodsClinical, procedural and imaging data were retrospectively reviewed for a consecutive series of patients at a single ...
Tan PS   +6 more
europepmc   +3 more sources

The Importance of Wall Apposition in Flow Diverters

open access: yesNeurosurgery, 2018
Abstract BACKGROUND It is assumed that high pore densities in flow diverters (FDs) are beneficial for intracranial aneurysm (IA) healing. However, various animal studies are not conclusive on the issue, suggesting that other factors are in play. One important factor might be wall apposition.
Aquarius, Rene   +7 more
openaire   +5 more sources

Failure of Flow Diverter Treatment of Intracranial Aneurysms Related to the Fetal-type Posterior Communicating Artery [PDF]

open access: yesNeurointervention, 2015
PurposeThe pipeline embolization device (PED) is a flow diverter that has shown promise in the treatment of intracranial aneurysms. Close to one-fifth of aneurysms, however, fail to occlude after PED placement.
Anderson Chun On Tsang   +5 more
doaj   +1 more source

Chronological Changes in Intra-aneurysmal Signal Intensity on T1-weighted Black Blood Images after Endovascular Treatment for Unruptured Intracranial Aneurysms

open access: yesNeurologia Medico-Chirurgica
Intra-aneurysmal thrombus formation is crucial for the healing of endovascularly treated aneurysms. This study evaluated whether T1-weighted black blood imaging can monitor thrombus formation by examining the relationship between chronological signal ...
Yukishige HASHIMOTO   +8 more
doaj   +1 more source

Tubridge flow diverter for the treatment of small and medium aneurysms

open access: yesFrontiers in Neurology, 2023
BackgroundTubridge flow diverter is a widely used device aimed at reconstructing parent arteries and occluding complex aneurysms in China. The experience of Tubridge in treating small and medium aneurysms is still limited.
Dajiang Xie   +9 more
doaj   +1 more source

A Review of Current Flow Diverters

open access: yesJournal of Neuroendovascular Therapy
Flow diverter (FD) devices are new-generation stents placed in the parent artery at the aneurysmal neck to obstruct intra-aneurysmal blood flow, thus favoring intra-aneurysmal thrombosis. In Japan, about eight years have passed since health insurance approval was granted for FD devices, and FD placement to treat aneurysms has become widespread ...
Yamada, Kiyofumi   +11 more
openaire   +2 more sources