Results 81 to 90 of about 8,717 (246)
E‐CAD: Electroactive Polymer‐Based Cardiac Assist Device with Low Power Consumption
Conventional cardiac assist devices often require high power, involve direct blood contact, and risk driveline infections. This work presents a soft electroactive polymer‐based system that compresses the heart externally while consuming <0.3 W. With no blood contact, a 0.3 mm driveline, and a compact design, E‐CAD demonstrates enhanced output and ...
Jiyeop Kim+4 more
wiley +1 more source
Abstract Autonomic nerves are crucial in cardiac function and pathology. However, data on the distribution of cholinergic and noradrenergic nerves in normal and pathologic human hearts is lacking. Nonfailing donor hearts were pressure‐perfusion fixed, imaged, and dissected. Left ventricular cardiomyopathy samples were also obtained.
Peter Hanna+15 more
wiley +1 more source
ABSTRACT Background Treating ostial left circumflex artery (LCx) lesions in percutaneous coronary intervention (PCI) for left main disease (LMD) remains a challenge. Despite recent recommendations for the use of drug‐coated balloon (DCB) in this lesion, there are concerns about crossover‐stenting from the left main trunk (LMT) to the left anterior ...
Takayuki Warisawa+10 more
wiley +1 more source
Ventricular fibrillation caused by massive right coronary air embolism: a case report
Background Coronary air embolism is a rare but severe complication of coronary interventions. Case presentation We present a case of a massive air embolism in the right coronary artery during percutaneous coronary intervention, resulting in ventricular ...
Hongcai Zhang+4 more
doaj +1 more source
ABSTRACT Aims Valve degeneration after DirectFlow implantation poses a challenge for valve‐in‐valve procedures due to its fragile polymeric structure and embolization risk. This study analyzes long‐term follow‐up of patients who underwent TAVI with DF to understand valve degeneration tendencies.
Dan M. Prunea+11 more
wiley +1 more source
ABSTRACT Background There is little data questioning the timing of intra‐aortic balloon pump (IABP) implantation in non‐cardiogenic shock patients undergoing high‐risk percutaneous procedures. Aims We compared prophylactic IABP (P‐IABP) implantation to an emergent, unplanned rescue use (R‐IABP) in high‐risk PCI. Methods Among 300 IAPB patients who were
Sascha d'Almeida+8 more
wiley +1 more source
ABSTRACT Background Little is known about stroke volume index (SVi) change and its prognostic implication in patients with low‐flow aortic stenosis (AS) undergoing aortic valve replacement (AVR) and conflicting results are present in literature. The aim of this study was to evaluate the postoperative change in SVi and its impact on outcomes in patients
Giorgio Fiore+14 more
wiley +1 more source
Background and Objective: Thrombolysis in myocardial infarction (TIMI) frame count (TFC) is an objective and quantitative index of coronary flow, and myocardial fractional flow reserve (FFR) is a lesion-specific index for epicardial coronary stenosis ...
A Gholoobi+3 more
doaj
Fractional flow reserve is a useful reference standard for myocardial perfusion studies with limitations [PDF]
Plein and Motwani1, in their editorial comment on a study by Ebersberger et al. 2 in the journal, state that because the ischaemia threshold of fractional flow reserve (FFR) was initially ‘validated’ in patients with unequivocal stress-induced ischaemia by stress SPECT/echocardiogram (ECHO),3 subsequent studies using FFR as a reference standard to ...
openaire +3 more sources
ABSTRACT Alcohol septal ablation (ASA) is a minimally invasive treatment option for patients with hypertrophic obstructive cardiomyopathy (HOCM) who remain symptomatic despite medical treatment and are either poor surgical candidates or prefer a less invasive approach.
Vishnu Bharani+3 more
wiley +1 more source