Results 71 to 80 of about 4,551,617 (315)
Finite Element Simulation and Performance Test of Residual Strength of Eccentric Wear Tubing
At present, the study of the effect of eccentric wear on the tubing strength mainly depends on the finite element simulation, which lacks physical test verification. The strength index of eccentric wear tubing lacks necessary test data support.
Ma Jianqiang +5 more
doaj
There have been several studies on analyses using finely meshed finite‐element (FE) models to understand in detail the behaviors of buildings during severe earthquakes.
Yasunori Mizushima +4 more
doaj +1 more source
Flame spread and smoke temperature of full-scale fire test of car fire
Full-scale experiments using two 4-door sedan passenger cars, placed side by side in the reverse direction, were carried out to establish the burning behavior and describe the spread of fire to adjacent car. The temperature was measured by thermocouples.
Dayan Li +5 more
doaj +1 more source
Hyperosmotic stress induces PARP1‐mediated HPF1‐dependent mono(ADP‐ribosyl)ation
Sorbitol‐induced hyperosmotic stress rapidly induces reversible mono(ADP‐ribosyl)ation (MARylation) on PARP1 without the signs of genotoxic signaling. We show that PARP1 autoMARylation is HPF1 dependent and forms hydroxylamine‐resistant O‐glycosidic linkages.
Anna Georgina Kopasz +11 more
wiley +1 more source
Loads Correlation of a Full-Scale Proprotor on the Tiltrotor Test Rig [PDF]
In 2018, a full-scale isolated proprotor test was conducted in the USAF National Full-Scale Aerodynamics Complex (NFAC) at NASA Ames. The test article was the 3-bladed Bell 699 research rotor derived from the AW609 rotor.
Kottapalli, Sesi
core +1 more source
An isoform of 14‐3‐3 protein regulates transbilayer lipid movement at the plasma membrane
Loss of 14‐3‐3ζ in CHO cells confers resistance to exogenous phosphatidylserine (PS) and impairs endocytosis‐independent inward flip‐flop of fluorescent PS at the plasma membrane. RNAi‐mediated knockdown reproduces this defect, while no additive effect is seen in ATP11C‐deficient cells.
Akiko Yamaji‐Hasegawa +3 more
wiley +1 more source
Digital collaborative exploration and practice of ground vibration test for full-scale aircraft
The ground vibration test of full-scale aircraft has the characteristics of multiple coordination units, complex system, long implementation time and high risk.
BAI Chunyu, LIANG Sen, SONG Qiaozhi
doaj +1 more source
Advanced recovery systems wind tunnel test report [PDF]
Pioneer Aerospace Corporation (PAC) conducted parafoil wind tunnel testing in the NASA-Ames 80 by 120 test sections of the National Full-Scale Aerodynamic Complex, Moffett Field, CA.
Geiger, R. H., Wailes, W. K.
core +1 more source
The ubiquitin ligase RNF115 is required for the clearance of damaged lysosomes
Upon lysosomal rupture, an E3 ubiquitin ligase RNF115 translocates from the cytosol to the damaged lysosomal membrane. Moreover, RNF115 depletion impairs the clearance of damaged lysosomes, identifying it as a key regulator of lysosomal quality control.
Sae Nakanaga +3 more
wiley +1 more source
A Framework for Predicting Fatigue Crack Initiation Life in Pipelines with Girth Welds
Current studies on fatigue crack initiation in pipelines remain relatively limited. Existing frameworks are confronted with issues including difficulties in crack monitoring and limited consideration of intragranular short-crack propagation.
Jianxing Yu +3 more
doaj +1 more source

