Results 91 to 100 of about 2,003,561 (167)

Digital Inference Method for Metal Particle Size Inside Gas Insulated Switchgear

open access: yesShanghai Jiaotong Daxue xuebao
Free metal particle defects are one of the frequent discharge defect types in gas insulated switchgear (GIS) equipment. Therefore, accurate estimation of their size and discharge severity is beneficial for understanding the insulation damage of equipment.
ZHANG Changhong, LI Weiguo, YANG Xu, LI Mingyang, WANG Miao, LUO Lin’gen
doaj   +1 more source

Application of SCNGO-VMD-SVM in Identification of Gas Insulated Switchgear Partial Discharge

open access: yesIEEE Access
Partial discharge (PD) is one of the main reasons of insulation deterioration in gas insulated switchgear (GIS). How to efficiently and accurately identify PD signals is an important guarantee for the stable operation of GIS.
Wei Sun, Hongzhong Ma, Sihan Wang
doaj   +1 more source

Simulation and Characterization of Micro-Discharge Phenomena Induced by Glitch Micro-Defects on an Insulated Pull Rod Surface

open access: yesEnergies
The reliability of GIS (gas-insulated switchgear) circuit breakers significantly depends on the condition of the insulated pull rods, with micro-defects on their surface posing a potential risk for micro-discharges and breakdown incidents. Experimentally
Shu Niu   +8 more
doaj   +1 more source

Characteristics investigation of R407C in high voltage applications as an alternative to SF6

open access: yesResults in Engineering
The concept of life without electrical power is not possible. All the industrial, domestic zones etc., requires power to operate, which is transmitted by means of overhead high voltage transmission lines from generating stations to sub-stations.
Imad M. Khattak   +7 more
doaj   +1 more source

Particle detector for gas insulated switchgear and the effect on environment

open access: yes, 2013
High voltage Gas Insulated Switchgear (GIS) is prone to metallic particles. The particle void can reduce the dielectric strength of the insulation material of SF6 gas.
Agos, M. F.   +2 more
core   +1 more source

Application of Optical Fiber Distributed Sensing System in Substation Maintenance

open access: yesGuangtongxin yanjiu, 2023
During daily operation of Substation, if Gas Insulated Switchgear (GIS)equipment breaks down, it will lead to the suspension of substation power supply, and national production and life cannot be guaranteed.
BAI Bin   +5 more
doaj  

3D Printing Technique-Improved Phase-Sensitive OTDR for Breakdown Discharge Detection of Gas-Insulated Switchgear. [PDF]

open access: yesSensors (Basel), 2020
Chen Z   +9 more
europepmc   +1 more source

Study on surface flashover characteristics of basin-type insulators under low-frequency transmission based on multiphysics coupling

open access: yesZhejiang dianli
To study the surface flashover characteristics of single-phase basin-type insulators in gas insulated metal-enclosed switchgear (GIS) under low-frequency transmission, an electro-thermal-fluid coupling simulation is employed.
LI Guoqiang   +6 more
doaj   +1 more source

PERANCANGAN GEDUNG GARDU INDUK GAS INSULATED SWITCHGEAR 150 KV JAKARTA TIMUR [PDF]

open access: yes, 2020
GIS (Gas Insulated Switchgear) adalah sebuah system penghubung dan pemutusJaringan listrik yang dikemas dalam sebuah tabung non ferro dan menggunakan bahan gas sulphumexaflouride (SF6) sebagai media isolasinya.Salah satunya adalah Gis kebon sirih II 150 ...
Andryansyah, -, Destoni, Deri
core  