Results 91 to 100 of about 2,074 (217)

Partial discharge detection using low cost RTL-SDR model for wideband spectrum sensing [PDF]

open access: yes, 2016
Partial discharge (PD) is one of the predominant factors to be controlled to ensure reliability and undisrupted functions of power generators, motors, Gas Insulated Switchgear (GIS) and grid connected power distribution equipment, especially in the ...
Atkinson, D. S. W.   +13 more
core   +3 more sources

Emerging Field Grading Spacer Magnetron Sputtered with a CCTO Layer for DC GIL/GIS

open access: yesCSEE Journal of Power and Energy Systems
Insulation failures of epoxy spacers applied in gas insulated transmission line/switchgear (GIL/GIS) often occur, primarily due to electric field distortion.
Jin Li   +5 more
doaj   +1 more source

A New Switching Impulse Generator Based on Transformer Boosting and Insulated Gate Bipolar Transistor Trigger Control [PDF]

open access: yes, 2016
To make the switching impulse (SI) generator more compact, portable and feasible in field tests, a new approach based on transformer boosting was developed.
Albarracín Sánchez, Ricardo   +4 more
core   +3 more sources

Detection of trace CF4 in C4F7N‐insulated gas‐insulated metal‐enclosed switchgear: Cascading specific chemical reactions with photoacoustic spectroscopy

open access: yesHigh Voltage
CF4 is a major decomposition product of the insulating gas in C4F7N‐insulated gas‐insulated metal‐enclosed switchgear (GIS) during partial discharge or overheating faults.
Zhicheng Wu   +6 more
doaj   +1 more source

Effect of AC Pre-Charging of Epoxy Insulator on Flashover Properties in Eco-Friendly Binary Gas Mixtures

open access: yesEnergies
Metal particles and surface charge accumulation are considered the key factors that could trigger unexpected flashovers of insulators equipped in gas-insulated switchgear (GIS).
Jian Guan   +5 more
doaj   +1 more source

Compositional modelling of partial discharge pulse spectral characteristics [PDF]

open access: yes, 2013
Partial discharge (PD) monitoring is an established method for insulation health monitoring in high voltage plant. A number of different approaches to PD defect diagnosis have been developed to extract defect-specific information from PD pulse data in ...
Baker, Peter   +2 more
core   +1 more source

Nanocrystalline based Mitigation Technique for Very Fast Transient over Voltages in Gas Insulated Substations [PDF]

open access: yes, 2021
: in gas insulated substations, issue of very fast transient over voltages is very familiar problem because of its effects on live ultra-high voltage equipment.
et. al., R.Durga Rao,
core   +1 more source

Mechanical Wear Characteristics of 170 kV Gas-Insulated Switchgear Circuit-Breaker Contacts Before Arc Initiation: An Accelerated Lifetime Test Approach

open access: yesIEEE Access
This study investigates the mechanical wear characteristics of 170 kV gas-insulated switchgear (GIS) circuit breaker contacts by conducting accelerated life testing.
Jong-Geon Lee, Jae-Hong Koo
doaj   +1 more source

An Initial Topology of Multi-terminal HVDC Transmission System in Europe:A Case Study of the North-Sea Region [PDF]

open access: yes, 2016
In this paper, technical challenges for realizing offshore multi-terminal HVDC (MTDC) transmission system in Europe is evaluated. An offshore MTDC topology is projected by interconnecting point-to-point HVDC links with the same voltage level and ...
Bak, Claus Leth   +3 more
core   +2 more sources

Home - About - Disclaimer - Privacy