Charge Accumulation Characteristics of SF6-Epoxy Interface Under Negative Repetitive Nanosecond Pulses

open access: yesCSEE Journal of Power and Energy Systems
Repetitve nanosecond impulses in gas-insulated metal-enclosed switchgear (GIS) are likely to trigger inside flashover. Interface charges on the spacer in GIS are considered one of the main factors damaging insulation performance and may be induced by ...
Shaocong Wu   +6 more
doaj   +1 more source

Testing and commisioning of GIS switchgear for high voltage substation / Mohd Zulkifli Mat Ghani [PDF]

open access: yes, 2003
This project presents a testing and commissioning of high voltage substation. The project focus on Gas Insulated Switchgear (GIS) is come out and the result of testing obtained are compared with Air Insulated Switchgear (AIS).
Mat Ghani, Mohd Zulkifli
core  

Impact of Pressure and Temperature on Charge Accumulation Characteristics of Insulators in Direct-Current Gas-Insulated Switchgear

open access: yesEnergies
Direct-current gas-insulated switchgear (DC GIS) is an important device for promoting the lightweight and compact design of offshore wind power platforms.
Lu Xu, Yixuan Li, Yan Zhu, Jianning Yin
doaj   +1 more source

Condition assessment method of GIS disconnector based on vibration- thermal-electrical multi-parameter signal characteristics

open access: yes电力工程技术
The disconnector fault in gas insulated switchgear (GIS) is commonly caused by the combined effects of mechanical, thermal, and electrical factors. Throughout the progression from defect development to a severe fault, various signals, including abnormal ...
ZHOU Xiu   +5 more
doaj   +1 more source

Analysis of SF6 decomposed products by fibre‐enhanced Raman spectroscopy for gas‐insulated switchgear diagnosis

open access: yesHigh Voltage
Sulphur hexafluoride (SF6) decomposed products analysis is highly critical in the early‐stage fault diagnosis of gas‐insulated switchgear (GIS). Spectrum technology outperforms traditional methods on non‐invasiveness, no sample preparation, and no ...
Jianxin Wang   +6 more
doaj   +1 more source

Characteristics investigation of R407C in high voltage applications as an alternative to SF6

open access: yesResults in Engineering
The concept of life without electrical power is not possible. All the industrial, domestic zones etc., requires power to operate, which is transmitted by means of overhead high voltage transmission lines from generating stations to sub-stations.
Imad M. Khattak   +7 more
doaj   +1 more source

Digital Inference Method for Metal Particle Size Inside Gas Insulated Switchgear

open access: yesShanghai Jiaotong Daxue xuebao
Free metal particle defects are one of the frequent discharge defect types in gas insulated switchgear (GIS) equipment. Therefore, accurate estimation of their size and discharge severity is beneficial for understanding the insulation damage of equipment.
ZHANG Changhong, LI Weiguo, YANG Xu, LI Mingyang, WANG Miao, LUO Lin’gen
doaj   +1 more source

Silicone Grease for Outdoor Gas-insulated Switchgear (GIS) Application

open access: yesIOP Conference Series: Materials Science and Engineering, 2018
Liang Song   +3 more
openaire   +1 more source

Contaminating Particle Movement in Insulating SF6 Gas in Gas Insulated Switchgear (GIS)

open access: yesInternational Journal of Electrical and Electronics Engineering, 2015
Sherif Ghoneim   +3 more
openaire   +1 more source