Results 101 to 110 of about 952 (202)

Research on lightning over-voltage in 1000kV gas insulated switchgear substation

open access: yes, 2012
This paper investigates the lightning over-voltage process of a 1000 kV ultra-high voltage(UHV) gas insulated switchgear(GIS) substation by the help of one electromagnetic transient simulation software, Electromagnetic Transients Program-Alternative ...
Hu, J, Xu, W, Zhang, Y, Zhu, J, Liu, N
core   +1 more source

Characteristics investigation of R407C in high voltage applications as an alternative to SF6

open access: yesResults in Engineering
The concept of life without electrical power is not possible. All the industrial, domestic zones etc., requires power to operate, which is transmitted by means of overhead high voltage transmission lines from generating stations to sub-stations.
Imad M. Khattak   +7 more
doaj   +1 more source

Studi Perancangan Pemutus Daya Pada GIS (Gas Insulated Switchgear) 500 kV di PT. YTL Jawa Timur PLTU Paiton Unit 6

open access: yes, 2011
ABSTRAK  Fandy Achmad 2011. Studi Perancangan Pemutus Daya Pada GIS (Gas Insulated swichgear) 500 KV di PT. YTL Jawa Timur PLTU Paiton unit 6. Tugas Akhir, Jurusan Teknik Elektro Fakultas Teknik Universitas Negeri Malang. Pembimbing : Yuni Rahmawati, S.T.
Fandy Achmad; Perpustakaan UM
core  

Partial Discharge Pattern Recognition of Gas-Insulated Switchgear via a Light-Scale Convolutional Neural Network

open access: yes, 2019
Partial discharge (PD) is one of the major form expressions of gas-insulated switchgear (GIS) insulation defects. Because PD will accelerate equipment aging, online monitoring and fault diagnosis plays a significant role in ensuring safe and reliable ...
Tingliang Liu   +5 more
core   +1 more source

Condition assessment method of GIS disconnector based on vibration- thermal-electrical multi-parameter signal characteristics

open access: yes电力工程技术
The disconnector fault in gas insulated switchgear (GIS) is commonly caused by the combined effects of mechanical, thermal, and electrical factors. Throughout the progression from defect development to a severe fault, various signals, including abnormal ...
ZHOU Xiu   +5 more
doaj   +1 more source

Digital Inference Method for Metal Particle Size Inside Gas Insulated Switchgear

open access: yesShanghai Jiaotong Daxue xuebao
Free metal particle defects are one of the frequent discharge defect types in gas insulated switchgear (GIS) equipment. Therefore, accurate estimation of their size and discharge severity is beneficial for understanding the insulation damage of equipment.
ZHANG Changhong, LI Weiguo, YANG Xu, LI Mingyang, WANG Miao, LUO Lin’gen
doaj   +1 more source

Silicone Grease for Outdoor Gas-insulated Switchgear (GIS) Application

open access: yesIOP Conference Series: Materials Science and Engineering, 2018
Liang Song   +3 more
openaire   +1 more source

Contaminating Particle Movement in Insulating SF6 Gas in Gas Insulated Switchgear (GIS)

open access: yesInternational Journal of Electrical and Electronics Engineering, 2015
Sherif Ghoneim   +3 more
openaire   +1 more source

Analysis of sulphur-hexafluoride leakage in substation with gas-insulated configuration

open access: yes
Diplomsko delo se osredotoča na problem določanja stopnje puščanja izolacijskega plina v plinskih predelkih GIS (angl. Gas Insulated Switchgear) stikališča.
Ljubič, Gašper
core  

Gas insulated substations

open access: yes, 2014
This book provides an overview on the particular development steps of gas insulated high-voltage switchgear, and is based on the information given with the editor's tutorial. The theory is kept low only as much as it is needed to understand gas insulated
Koch, Hermann
core  